B&B Electronics MDR-40-24 Leaflet

Page of 2
SPECIFICATION
MDR-40-5
MDR-40-12
MDR-40-24
MDR-40-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
WORKING HUMIDITY
WORKING TEMP.
DC OK SIGNAL
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V
12V
24V
48V
6A
3.33A
1.7A
0.83A
0 ~ 6A
0 ~ 3.33A
0 ~ 1.7A
0 ~ 0.83A
30W
40W
40.8W
39.8W
80mVp-p
120mVp-p
150mVp-p
24 ~ 30V
200mVp-p
48 ~ 56V
2.0%
1.0%
1.0%
1.0%
12 ~ 15V
5 ~ 6V
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
500ms, 30ms/230VAC
500ms, 30ms/115VAC at full load
50ms/230VAC
20ms/115VAC at full load
85 ~ 264VAC
120 ~ 370VDC
47 ~ 63Hz
78%
86%
88%
88%
1.1A/115VAC
0.7A/230VAC
COLD START 30A/115VAC
60A/230VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6.25 ~ 7.25V
Protection type : Shut down o/p voltage, re-power on to recover
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
-20 ~ +70
(Refer to output load derating curve)
Relay contact rating(max.): 30V/1A resistive
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
Component :
each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
10 ~ 500Hz, 2G 10min./1cycle, period for 60min.
301.7K hrs min.
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:MDR-40-SPEC 2007-07-09
UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (12V,24V,48V only)
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
40W Single Output Industrial DIN Rail Power Supply
M D R - 4 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
PROTECTION
SAFETY &
FUNCTION
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
NEC class 2 / LPS compliant (12V,24V,48V only)
LED indicator for power on
DC OK relay contact
No load power consumption<0.75W
100% full load burn-in test
3 years warranty
Features :
40*90*100mm (W*H*D)
0.3Kg; 42pcs/13.6Kg/0.82CUFT
LEAKAGE CURRENT
<1mA / 240VAC
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25
70%RH