Panasonic CS-XE7PKEW Leaflet

Page of 2
Kit Silver Plated
KIT-XE7-PKE
KIT-XE9-PKE
KIT-XE12-PKE
KIT-XE15-PKE
Kit Silver Plated / with Smartphone Control
KIT-XE7-PKE-WIFI
KIT-XE9-PKE-WIFI
KIT-XE12-PKE-WIFI
KIT-XE15-PKE-WIFI
Kit White
KIT-E7-PKE
KIT-E9-PKE
KIT-E12-PKE
KIT-E15-PKE
Kit White / with Smartphone Control
KIT-E7-PKE-WIFI
KIT-E9-PKE-WIFI
KIT-E12-PKE-WIFI
KIT-E15-PKE-WIFI
Indoor Silver plated
CS-XE7PKEW
CS-XE9PKEW
CS-XE12PKEW
CS-XE15PKEW
Indoor White
CS-E7PKEW
CS-E9PKEW
CS-E12PKEW
CS-E15PKEW
Outdoor
CU-E7PKE
CU-E9PKE
CU-E12PKE
CU-E15PKE
Cooling capacity
Nominal (Min - Max)
kW
2.05 (0.75-2.40)
2.50 (0.85-3.00)
3.50 (0.85-4.00)
4.20 (0.85-5.00)
Nominal (Min - Max)
kCal/h
1,760 (650-2,060)
2,150 (730-2,580)
3,010 (730-3,440)
3,610 (730-4,300)
EER 
1)
Nominal (Min - Max)
Energy Saving 4.41 (3.13-4.21) 
A
4.72 (3.47-4.17) 
A
4.12 (3,40-3.57) 
A
3.36 (3.27-3.23) 
A
SEER
Nominal
Energy Saving 6.7 
A++
6.6 
A++
6.6 
A++
5.9 
A+
Pdesign (cooling)
2.1
2.5
3.5
4.2
Power input Cooling
Nominal (Min - Max)
kW
0.465 (0.240-0.570)
0.530 (0.245-0.720)
0.850 (0.250-1.120)
1.25 (0.260-1.550)
Annual Energy Consumption (Cooling) 
2)
kWh
110
133
186
249
Heating capacity
Nominal (Min - Max)
kW
2.80 (0.75-4.00)
3.40 (0.85-5.00)
4.00 (0.85-6.00)
5.30 (0.85-6.80)
Heating capacity at -7 °C
Nominal
kW
2.35
2.88
3.37
4.11
COP 
1)
Nominal (Min - Max)
Energy Saving 4.44 (3.26-3.96) 
A
4.66 (3.54-3.88) 
A
4.32 (3.47-3.55) 
A
3.71 (3.33-3.52) 
A
SCOP
Nominal
Energy Saving 4.3 
A+
4.1 
A+
4.0 
A+
3.6 A
Pdesign at -10 °C
kW
2.1
2.7
3.2
3.6
Power input Heating
Nominal (Min - Max)
kW
0.630 (0.230-1.01)
0.730 (0.240-1.29)
0.925 (0.245-1.690)
1.430 (0.255-1.930)
Annual Energy Consumption (Heating) 
2)
kWh
684
922
1120
1400
Indoor Unit
Power source
V
230
230
230
230
Recommended Fuse
A
Recommended power cable section
mm²
Connection indoor / outdoor
mm²
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
Current (Nominal)
Cooling / Heating
A
2.15 / 2.85
2,4 / 3.35
3.80 / 4.10
5.50 / 6.40
Max. current
A
4.5
5,7
7.6
8.8
Air Volume
Cooling / Heating
m³/h
732 / 768
762 / 786
834 / 858
846 / 900
Moisture removal volume
l/h
1.3
1.5
2
2.4
Sound pressure Level 
2)
Cooling (Hi / Lo / S-Lo) dB(A)
37 / 24 / 20
39 / 25 / 20
42 / 28 / 20
43 / 31 / 25
Heating (Hi / Lo / S-Lo) dB(A)
38 / 25 / 20
40 / 27 / 20
42 / 33 / 20
43 / 35 / 29
Sound power Level
Liquid pipe / Gas pipe
dB
53 / 54
55 / 56
58 / 58
59 / 59
Dimensions 
3)
H x W x D
mm
295 x 870 x 255
295 x 870 x 255
295 x 870 x 255
295 x 870 x 255
Net weight
Kg
10
10
10
10
Air purifier filter
Nanoe-G
Nanoe-G
Nanoe-G
Nanoe-G
Outdoor Unit
Air Volume
Cooling / Heating
m³/h
2,034 / 2,034
1,788 / 1,788
1,998 / 1,998
1,998 / 1,998
Sound pressure Level
2)
Cooling / Heating (Hi)
dB(A)
45 / 46
46 / 47
48 / 50
49 / 51
Sound power Level
Cooling / Heating (Hi)
dB
60 / 61
61 / 62
63 / 65
64 / 66
Dimensions 
3)
H x W x D
mm
542 x 780 x 289
542 x 780 x 289
619 x 824 x 299
619 x 824 x 299
Net weight
Kg
31
33
34
33
Piping connections
Liquid pipe / Gas pipe
inch (mm)
1/4 (6.35) / 3/8 (9.52) 
1/4 (6.35)  / 3/8 (9.52) 
1/4 (6.35)  / 3/8 (9.52) 
1/4 (6.35) / 1/2 (12.70)
Refrigerant Loading
R410A (GWP value)
Kg
0.830
1.00
1.05
1.02
Elevation difference (in/out) 
4)
Max
m
15
15
15
15
Piping length
Min / Max
m
3-15
3-15
3-15
3-15
Piping length without 
refrigerant increase
Max
m
7.5
7.5
7.5
7.5
Additional gas
g/m
20
20
20
20
Operating range
Cooling Min / Max
°C
-10 / +43
-10 / +43
-10 / +43
-10 / +43
Heating Min / Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24
Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding 
efficiency, comfort and healthy air combined with state-of-the-art design.
Econavi features an in-built human activity sensor and a new sunlight detection technology to adjust output 
thereby giving you the best comfort at anytime whilst saving energy. Econavi not only optimizes air flow 
orientation and volume according to human presence, it also reduces cooling power automatically by no/less 
sunshine. With econavi, you will achieve up to 38% energy savings whilst increasing your comfort.
Furthermore, the Nanoe-G revolutionary air-purifying system utilises nano technology fine particles to remove 
and deactivate 99% of both airborne and adhesive micro-organisms like bacteria, viruses and mould.
WALL MOUNTED ETHEREA
INVERTER+
SILVER PLATED / WHITE
INTERNET CONTROL READY: Optional. MILD DRY: Maintains a Relative Humidity up to 10% higher than cooling operation. Ideal when sleeping with the air conditioner on. SUPER QUIET: For XE7, XE9, XE12, E7, E9 and XE12
Awarded with the prestigious
IF Design Award 2013
A
 class
energy saving
SUPER QUIET
Silent air
20 dB
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Up to 
38%
energy savings
(cooling)
Air purifier 
99%
 
removal
bacteria · virus · mold
Perfect
humidity
control
MILD DRY
Improved
comfort
AUTOCOMFORT
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with PKE units.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
34