Polycom 2457-26122-001 User Manual

Page of 280
Integrator’s Reference Manual for the Polycom RealPresence Group Series 
252
Polycom, Inc.
 
Remote Control
This section provides information about the IR signals for Polycom 
RealPresence Group systems.
Notes
• Wake up – 2.6 ms on; 2.6 ms off
• 0–559 µs (22 pulses at 38 KHz) on; 845 µs (33 pulses at 38 KHz) off
• 1–845 µs (33 pulses at 38 KHz) on; 1192 µs (46 pulses at 38 KHz) off
• EOM–559 µs (22 pulses at 38 KHz) on
• System Code consists of a User ID field (upper nibble) and the Polycom 
Vender Code (lower nibble) with value 0x5. The default User ID value is 
0x3, so the default System Code value is 00110101 or 0x35.
• Parity is a 2-bit field consisting of a parity bit (b1) and a toggle bit (b0). 
Parity is even.
• Inter-burst timing is 2200 pulse times at 38.062 KHz or 57.8 ms
• 38.062 KHz signal is at 1/3 duty cycle to LED
• Multi-bit fields are transmitted most significant bit first
• Bits are labeled b0..bn, where b0 is the least significant bit
Protocol is: <Wake up> + <System Code> + <Key Code> + <Parity> + <EOM>
This information is provided for reference only. Polycom claims no responsibility 
or liability for programmed third-party remote control devices.
Key Name
Key Code
Key Code
Parity
#
1100
0CH
Even
*
1011
0BH
Odd
0
110000
30H
Even
1
110001
31H
Odd
2
110010
32H
Odd
3
110011
33H
Even
4
110100
34H
Odd
5
110101
35H
Even
6
110110
36H
Even