Avaya Integral 5 Easy BND AR2.X 4999108488 User Manual

Product codes
4999108488
Page of 254
06/07
134
4.999.112.593
Installation manual Integral 5 D/E easy
PB1 (emergency power supply)
Further information on the charging phase 
Further information on the charging phase
PB1 is installed, battery is connected, the supplied, coded SV cable between PB1 and BNx is 
plugged in: 
the status of the PB1 is signalled after inserting the plug-in mains unit as follows: 
 The initialization phase begins (phase 1)
 
 LED flashes very rapidly (duration approx. 10 sec.) -----> after which
 
    the LED
 
 in the case of a NiCd battery is unlit (also for approx. 10 sec.)
 
 in the case of a lead gel battery remains on -----> after which the LED
 
    starts to flash (pulse) once a second
 
 When it is detected that a battery is connected, the charging phase
 
    begins (phase 2); the number of flash pulses changes during 
 
    the charging phase
 
 At the start of the charging phase (a) the number flash pulses is high
 
    (x
n
 pulses) LED 5sec. on > x
n
 pulses > LED 5 sec. on > x
n
 pulses etc.
    and decreases towards the end of the charging phase (b)
After the battery has been charged (phase 3), the LED flashes at a constant rate (b), i.e.
LED 5sec. on ---> 1 pulse ---> LED 5 sec. on ---> 1 pulse etc.