Avaya Integral 5 Easy BND AR2.X 4999108488 User Manual

Product codes
4999108488
Page of 254
06/07
196
4.999.112.593
Installation manual Integral 5 D/E easy
Installation examples I5 D easy
Example 2 – BND plus EXE - maximum S0 expansion
Explanation of example 2
On a BND it is possible to drive IOM plug-in modules and also LAN plug-in modules. Slots 2, 4, 6 and 8 are designed so that they can drive IOM plug-in 
modules (without switching matrix) or intelligent LAN plug-in modules (with switching matrix).
On the EXE, IOM or LAN plug-in modules can be driven only if the EXE is also attached to the IOM and / or LAN connections of the BNx which is driving 
them. In the diagram the IOM channels of the BND are provided on the EXE, so that 2 x (8 x 2B) are available for IOM use.
 
Since the BND has no LAN connection available, no LAN plug-in modules can be driven by the EXE, therefore here only IOM plug-in modules.
In the upper diagram the maximum S0 expansion has been selected; other permutations can be found in the "Summary of items for fitting to BND/EXE".
All modules must be earthed. 
 
Since the BND has no power supply output, the plug-in mains unit is now plugged into the EXE. From there the BND is fed using a power cable from the EXE.
Displ. module
B channels
Tele-
phones
Exchan
ges
1 x MS4
8
4  x  S0
4  x  T0
7 x SXS
56
56 x S0
Total
64
60
4 x T0
  
Except where the connections of the EXE are purely analog2 IOM connections should always be made from the BND to the EXE.
I5 D easy EXE
S8P
8x2B
S8P
8x2B
IOM
L R
o i
LAN
MS4
4x2B
I5 D easy BND
S8P
8x2B
V.24
IOM
1
2