Avaya Integral 5 Easy BNE AR2.X 4999108480 User Manual
Product codes
4999108480
Installation manual Integral 5 D/E easy
Plug-in module MA2 (IOM, I5 D/E)
06/07
119
4.999.112.593
Short description of the MA2 subscriber connection
Short description of the MA2 subscriber connection
Feed current 20..40 mA (country-specific configuration using variant fittings)
Ringing voltage (35...40 Veff)
Feed polarity reversal
Loop current identification (flash, on-hook, off-hook)
Ranges for telephone station feed with –40 V, permissible cable resistance included
Instrument resistance 800 Ohm
Ranges when using 20 mA:
with installation cable with 0.4 mm Ø up to approx. 1350 m
with installation cable with 0.6 mm Ø up to approx. 2900 m
CLIP display on subscriber instrument
Only Austria:
Analog direct dial-in possible
- Inward dialling of an analog exchange line in accordance with the ÜFS standard.
Direct dialling to a system subscriber possible (corresponds to point-to-point connection on
an analog basis).