78
4.999.112.593
Installation manual Integral 5 D/E easy
Basic module BNS (slave module for I5 E easy)
Short description BNS (slave module)
Short description of BNE
Function
Slave module for I5 easy. This is the last module for connection to the LAN channels. It undertakes independently the management of its own local IOM 
channels.
Slots
There are 4 slots on the BNS
Slot 2 (slot address 1)
Slot 4 (slot address 3)
Slot 6 (slot address 5)
Slot 8 (slot address 7)
Plug-in 
modules
2-slot and / or 4-slot plug-in module (IOM and LAN)
 
Single 1-slot plug-in module "DIA" (IOM)
IOM
IOM is a connection local to BNS, which is available at all slots. IOM modules can be driven through this connection. IIOM modules have no 
switching matrix control of their own and are generally controlled only by the BNS through the IOM connection. Max. 96 IOM channels, 48 per 
BNE/BNS
For an IOM extension using EXE modules, 4 sockets EXP1 thro EXP4 are provided. Each socket drives 8 x 2B channels (16 B channels) for fur-
ther applications
LAN
LAN is a 128 B channel connection, which is available at all slots. LAN modules that are connected "draw" this connection from their total of avail-
able B channels.
LAN modules are intelligent plug-in modules with their own switching matrix control
The LAN connection is not brought out from the BNS for further applications, i.e. no LAN connections can be used on an EXE connected to the 
BNS
Note
4-slot plug-in module at slot 4 and 8, V24 available only at slot 2 (module V24)
BNS has a cold-start switch, which is accessed through a hole in the casing. There is no "cold-start plug".
Local reset for the BNS, no time-based differentiation as offered on BND/BNE.
Left hand / right hand LEDs, see "LEDs on the BNS" on the back
The BNS can be powered using a separate plug-in mains unit (Vin) or it can be fed from another EXE module (Vin). See plug-in mains unit
Max. 1 x CV1 and max. 1 x T8S on a BND. 1 x CV1 plus 1 x T8S permissible on a BND.
Max 4 x EXE between BNE and BNS using LAN