Plug-in module DSI (IOM, I5 D/E)
Short description DSI, DHI, FSP
The description of the connection of the Door stations is found in appendix 1.
Short description DSI, DHI, FSP
Function
 1x door station, 2-wire or 4-wire (SW switchable)
 
 1x FSP = free switching points plus sensor input
Width
2-slot width
Connection 
options
BND, BNE, BNS, EXE all slots
Cables
2 x patch cables
Note
 DHI and FSP functions available concurrently
 
 DHI for connection to a 2-wire or 4-wire door station
 
 DHI 4-wire and DHI 2-wire are software switchable
 
 Door stations from Siedle and Grothe can be directly connected with no adaptation
 
 Can also be used by floor (multi-family systems)
 
 The door station module can incorporate a suitable amplifier both for the microphone and
 
    also for the speaker
 
 FSP with 3 free switching points and 1 potential-free sensor input
 
 Max. permissible voltage at the switching points: < 30 Veff or < 60 V DC
 
 Max permissible current at the switching points: 1A
 
 At the potential-free sensor input a voltage of >7.3 V .. 20 V AC or DC must be present; 
 
    this corresponds to an input current of >1 mA, which activates the sensor
 
 
 There must be no transfer of mains voltage to the system via the Western socket.