Installation manual Integral 5 D/E easy
Commissioning
Extending with EXE, BNS, IPU / substituting a BNx, EXE, IPU
Extending with EXE, BNS, IPU / substituting a BNx, EXE, IPU
If the customer wishes to expand the system by an EXE or BNx or IP module or replace a BNx/EXE or an 
IP module, it is essential to comply with the following instructions / steps:
 The entire system must be disconnected from the power supply before it is expanded by an
 
    EXE, a BNx or an IP module, or before an EXE / BNx or an IP module is exchanged.
 Never unplug or plug in a live IOM or LAN extension cable.
 General information:
The Integral 5 easy must always be connected via a common power outlet (individual EXE and 
BNx components and IP modules may be damaged if they are connected to different power 
circuits)
All plug-in modules can be unplugged and plugged whilst they are electrically live, and they will 
not be damaged thereby – but the functionality of the system can be deranged by plugging and 
unplugging modules!