178
4.999.112.593
Installation manual Integral 5 D/E easy
Plug-in module T8S (IOM, I5 D/E)
 
Short description T8S
Short description of S8D
Function
 4 digital connection units each with 2 B channels, software configurable as T0 / S0
 
       8 S0 subs
 
       7 S0 subs and 1 T0 exchange line
 
       6 S0 subs and 2 T0 exchange lines
 
       5 S0 subs and 3 T0 exchange lines
 
       4 S0 subs and 4 T0 exchange lines
 
 On powering up the system, the T8S is always configured as 4 S0 subs and 4 T0 exchange lines
 
Width
4-slot width
Connection 
options
 max. 1 x on a BND, slot 4 and 8
 
 BNE, BNS, slot 4 and 8
 
 EXE slot 2 and 4
Cables
4 x Y patch cable
Note
 The attachment of the NTBA to terminals configured for S0 operation can lead to damage to the
 
   NTBA.
 
 Care must be taken that the Western plug of an S0 subscriber is not inserted into the T0 exchange
 
   configured interface (Western socket).
 
 T0 can be reprogrammed to S0 using codes #5 and #6 (see the manual under Data Entry).
 
 Make absolutely sure prior to re-programming from T0 to S0 that there is no NTBA connected to the
 
   relevant Western sockets.
 
 An NTBA may only be connected to (plugged into) those Western sockets that are configured for the
 
   T0 connection.
 
  In order to be quite certain of this, attach the NTBA only after the system has been put into operation.
S01
S02
S03
S04
S05
S06
S07
S08
Exch
Exch
Exch
Exch
Sub
Sub
Sub
Sub