Avaya Integral 5 Easy BND AR2.X 4999108491 User Manual

Product codes
4999108491
Page of 254
06/07
232
4.999.112.593
Installation manual Integral 5 D/E easy
Technical Data
Connection specification for a/b subscriber
 
 Connection specifications for DECT subscriber
Connection specification for a/b subscriber
a/b Interface
 Feed voltage: –40 V
 
 Feed current: approx. 20 mA
 
 Permissible line resistance: 550 Ohm (incl. device)
Ranges for 2 x 130 Ohm line 
resistance:
 Installation cable 0.4 mm
2
 (J-Y(St)Y2x2x0.4): approx. 1350 m 
 
 Installation cable 0.6 mm
2
 (J-Y(St)Y2x2x0.6): approx. 2900 m 
Connection specifications for DECT subscriber
UPD Interface (4-wire):
 Feed voltage: –40 V
 
 Transmission rate: 4xB per 64 kBit/s and 2xD per 16 kBit/s 
 
 Bit rate on lines: 384 kBit/s in send and receive directions 
 Ranges with 4 x 100 Ohm, installation cable 0.6 mm
J-Y(St)Y2 x 2 x 0.6)
 
 Point to point connection: approx. 1,000 m