Avaya Integral 5 Easy BND AR2.X 4999108487 User Manual

Product codes
4999108487
Page of 254
06/07
124
4.999.112.593
Installation manual Integral 5 D/E easy
Plug-in module MS4 (IOM, I5 D/E)
Short description of MS4
Short description of module
Short description of exchange connection
Short description of subscriber connection
Short description of module
Function
2 x T0, 2 x S0
Width
2-slot width
Connection options
 BND: max. 2 x per system
 
 BNE/BNS: max. 2 x
 
 BND, BNE, BNS, all slots
Cables
2 x Y patch cables
Note
 Left hand socket: 2 x T0
 
 Right hand socket: 2 x S0, each terminated with 100 Ohm
 
 Unplugging and plugging in under power is permissible
Short description of exchange connection
 Left hand socket: 2 x T0, the T0 connection does not require a power supply
 
 No 100 Ohm termination, no earth reference for the rough lightning strike protection, insulation principle
 
 Without exchange synchronisation operates at high precision internal clock, otherwise synchronised 
 
    
to the exchange
 
 T0 data see T8S
Short description of subscriber connection
 Right hand socket: 2 x S0, each terminated with 100 Ohm
 Range: Point to point: <= 1000m, shorter passive bus: <= 100m, extended passive bus: <= 500 m
 See SXS for further data