162
4.999.112.593
Installation manual Integral 5 D/E easy
Plug-in module S8D (LAN, I5 E)
Short description of S8D
Short description of S8D
Function
 8 x UPD ports for 4 x DECT-RBS
 
 7 B channels ADPCM per RBS
 
 4 digital speech processors (DSP) allowing 28 simultaneously 
 
    processed speech channels.
 
 Power supply, message exchange (LAN) as well as speech 
 
    transmission (PCM highway) via D-sub plug.
Width
4-slot width
Connection 
options
 EXE slot 2 or 4, max. 1 x per system 
Cables
2 x Y patch cables
Note
 If an S8D is plugged into an EXE, the EXE must have its own plug-in
 
    mains unit.
 The module become hot on the underside (metal cover) (approx. 60 °C).
 