Installation manual Integral 5 D/E easy
Installation examples I5 D easy
06/07
201
4.999.112.593
Explanation of example 5
Since the BND has no external LAN connection, no LAN plug-in modules can be driven by the EXE.
The items attached to the EXE are here purely analog.
Therefore here also it applies that:
Furthermore, because of the DECT connections:
In the upper diagram the maximum DECT expansion has been selected; other permutations can be found in the "Summary of items for fitting to BND/EXE".
All modules must be earthed. 
Only are where the connections of the EXE purely analog is a singleton IOM connection BND-EXE permissible.
 
Except where the connections of the EXE are purely analog2 IOM connections should always be made from the BND 
 
to the EXE.
Max. 8 x RBS are permissible within the system
 (in the example there are also 8 x RBS).
One module with DECT module(s) requires its own power supply.