Avaya Integral 5 Easy BND AR2.X 4999108487 User Manual

Product codes
4999108487
Page of 254
06/07
214
4.999.112.593
Installation manual Integral 5 D/E easy
Installation examples I5 E easy
Explanation of example 2
In principle, the layout of example 2 is similar to that of example 1, the difference lies in the connection of a further EXE to the BNE and the BNS.
Each EXE takes up the max. possible number of IOM channels from the BNE/BNS.
No LAN operation is possible on the EXE.
In the upper diagram the maximum UPN expansion has been selected; other permutations can be found in the "Summary of items for fitting to BNE/BNS/EXE".
All modules must be earthed. 
Since each plug-in mains unit can feed only a maximum of 2 modules, the BNE/BNS is now supplied using its own plug-in mains unit. Both EXE units share 
their own plug-in mains unit, which is plugged into the first EXE unit. The Vout on the first EXE provides the power to the second EXE (Vin).
.
Displ. module
B channels
Telephones
Exchanges
4 x MS4
32
16 x S0
16 x T0
10 x S8P
80
80 x UPN
Total
112
16 x S0 / 80 x UPN
16 x T0
  
Except where the connections of the EXE are purely analog2 IOM connections should always be made from the BND to the EXE.