RAID Overview 
The standard RAID system levels are 0, 1, 3, and 5. 
Stripe Size 
You write data in stripes across the multiple hard disks of a RAID. Since multiple disks are accessed at the 
same time, disk striping enhances performance. The stripes can vary in size and are interleaved sequentially.   
Term Definition 
Stripe Width 
The number of hard disk drives that are striped to. In a RAID with four hard disks the 
stripe width is four. 
Stripe Size 
The length of the interleaved data segments written across multiple hard disks. 
 
Example: 
Configure four hard disk drives as RAID 0 and the data is striped in segments. Segment One writes to  
HDD 1, Segment Two writes to HDD 2, and so on as below: 
HDD 1 
 
Segment One 
Segment Five  
Segment Nine 
HDD 2 
 
Segment Two 
Segment Six  
Segment Ten 
HDD 3 
 
Segment Three 
Segment Seven  
Segment Eleven 
HDD 4 
 
Segment Four 
Segment Eight  
Segment Twelve