Parameter Symbol 
Min Typ
Max 
Units
Notes/Conditions 
I
2
C Clock Speed 
 
 
100,000 
Hz 
Bus can be driven blind 
Accuracy 
Internal Transceiver 
Temperature 
DD
Temperature
-3 
 
+3 
°C 
Measured at controller IC 
Internal Transceiver 
Supply Voltage 
DD
Voltage
-3 
 
+3 
Measured at controller IC 
Tx Bias Current 
DD
Bias
-10   +10  % 
 
Tx Output Power 
DD
TxPower
-3 
 
+3 
dB 
100% tested in production 
tested at room temp to 
±2 dB 
Received Average 
Power 
DD
RxPower
-3 
 
+3 
dB 
100% tested in production 
tested at room temp to 
±2 dB 
Range 
Internal Transceiver 
Temperature 
DD
Temperature
-40   100  °C 
 
Internal Transceiver 
Supply Voltage 
DD
Voltage
3.0   6.0  V 
 
Tx Bias Current 
DD
Bias
0   80 mA 
 
Tx Output Power 
DD
TxPower
-13.5  
1  dBm 
 
Received Average 
Power 
DD
RxPower
-24  
1  dBm 
 
 
Table 9. Digital Diagnostic Accuracy and Range Limits