Mounting
Mount the DS1108i detector on the ceiling, or on the
wall opposite or adjacent to the window. Coverage
depends on room acoustics and window size.
Standard Coverage
7.6 m (25 ft) for glass sizes over 30.5 cm x 30.5 cm
(12 in. x 12 in.).
Parts included
Quant.
Component
1
Detector
1
Literature – Installation Guide
Technical specifications
Electrical
Current:
21 mA nominal at 12 VDC
Voltage:
9 VDC to 15 VDC
Environmental
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
Mechanical
Dimensions
(HxDiameter):
2.1 cm x 8.6 cm (0.83 in. x 3.4 in.)
Material:
High‑impact ABS plastic enclosure
Outputs
Alarm:
Normally‑closed (NC) reed relay rated at 3.5 W,
125 mA at 28 VDC for resistive loads
Tamper:
Normally-closed (NC) cover‑activated tamper
switch with separate terminals. Contacts rated
at 28 VDC, 125  mA maximum.
Ordering information
DS1108i Glassbreak Detector
Round detector uses microprocessor-based sound
analysis technology (SAT) to listen for the specific
frequencies associated with breaking glass
Order number 
DS1108i
Accessories
DS1110i Glassbreak Tester
Used to test DS1101i, DS1102i, DS1103i, and DS1108i
Glass Break Detectors. Powered by a 9 V alkaline
battery (supplied).
Order number 
DS1110i
 