ABUS HSRM10000 Leaflet

Page of 2
ABUS Smoke Detector, Alkaline
Art. no. HSRM10000
•  Detection method: photoelectric reflection
•  Signal generator: Piezo with 85 dB(A) @ 3 m
•  Test button
•  Low battery warning
The photoelectrical ABUS smoke detector reacts to smoke particles. If too much smoke enters its measuring
chamber, a loud alarm signal is triggered. The smoke detector is mounted at the ceiling in the center of a room.
The minimum distance to the walls should be 15 cm, the distance to the corners at least 50 cm. The operation
range of the smoke detector is up to 40 m². We recommend installing one smoke detector each in the hall, the
stairways, living room, and bedroom. In the event of fire, the integrated powerful piezo sounder provides an
effective alarming – at a minimum sound level of 85 dB. When using a 9 V alkaline battery block, the lifetime is
up to 3 years (service interval for battery replacement). The battery lifetime varies depending on how often you
run the detector's function test. This is done easily by pressing the function test button. It is recommended to
test the detector once a week. The detector registers low battery and then issues regular beep tones. The home
smoke detector is VdS certified. This guarantees high safety standards.
Technical Data:
Dimensions
(HxD) 34x102 mm
Display
LED 
Battery type
Block battery 
Width
102 mm
Type of detection
Photoelectric reflection 
Detection range of detector
(m2)
40 m²
Housing material
ABS 
Height
34 mm
Max. battery life
3 year(s)
Max. operating
temperature
45 °C
Min. operating
temperature
0 °C
Installation location
Ceiling 
Net weight
0.18 kg
Sensor type
Photodiode 
Voltage monitoring
No 
DC voltage supply
9 V
Page 1 of 2