FSP/Fortron FSP300-60PLN Leaflet
FSP300-60PLN
300 WATT ACTIVE PFC
PC POWER SUPPLY
GENERAL SPECIFICATIONS
For P4 & Athlon
FEATURES
Temperature Range:
Temp. Coefficient:
Transient Response:
Transient Response:
Hold-up Time:
Dielectric Withstand:
Humidity:
Efficiency:
Power Good Signal:
Overload Protection:
Dimensions (mm):
Operating, 0°C to +50°C
Storage, -20°C to +80°C
Storage, -20°C to +80°C
0.01%/°C
Output voltage returns in less than 1mS
Output voltage returns in less than 1mS
max. following a 25% load change
17mS min. at full load & nominal input
17mS min. at full load & nominal input
voltage
Input to frame ground 1800 VAC for 1
Input to frame ground 1800 VAC for 1
second
95% RH
95% RH
65% min measured at normal AC main
voltage and frequency with maximum load
voltage and frequency with maximum load
on all output
Power on delay time 100mS to 500mS, off
Power on delay time 100mS to 500mS, off
delay 1mS minimum
150% maximum
150% maximum
86H x 150W x 140L
INPUT SPECIFICATIONS
♦ High efficiency
♦ Active PFC Circuit
♦ Power factor correction (PFC) meet EN61000-3-2
♦ Power factor correction (PFC) meet EN61000-3-2
♦ Internal 12 VDE fan
♦ Low Ripple & Noise
♦ Low Ripple & Noise
♦ Complies with FCC part 15 subpart J class B 115 VAC
operation and CISPR 22 class B 230 VAC operation
♦ Output over voltage protection
♦ Short circuit protection on all outputs
♦ MTBF above 100,000 hrs at 25°C
♦ MTBF above 100,000 hrs at 25°C
♦ 100% Hi-pot & ATE tested
♦ Resettable power shut down
♦ Resettable power shut down
♦ 100% burn-in under high ambient temperature 50°C)
♦ Approved by UL 1950 , CSA C22.2 Level 3, IEC 950,
♦ Approved by UL 1950 , CSA C22.2 Level 3, IEC 950,
VDE EN60950, NEMKO (CB Report), and CE
REMOTE ON/OFF CONTROL:
The power supply shall accept logic open collector levels that
will disable/enable all the output voltage (except +5V standby).
will disable/enable all the output voltage (except +5V standby).
As logic level is low/high, output voltages are enabled/disabled.
Voltage:
Frequency:
Input Current:
Input Current:
Inrush Current:
(+25° C cold start)
90 ~ 264 VAC, full range
47Hz ~ 63Hz
6A (RMS) for 115 VAC;
6A (RMS) for 115 VAC;
3A (RMS) for 230 VAC
60A max for 115 VAC
60A max for 115 VAC
90A max for 230 VAC
OUTPUT CHARACTERISTICS
Output Current
Regulation
Output Voltage
Minimum Load
Maximum Load
Load
Line
Ripple & Noise
*+3.3V
0.3A
28.0A
± 5 %
± 1 %
50mV
*+5V
0.1A
30.0A
± 5 %
± 1 %
50mV
*+12V
0.0A
15.0A
± 5 %
± 1 %
120mV
-5V
0.0A
0.3A
± 5 %
± 2 %
100mV
-12V
0.0A
0.8A
± 5 %
± 2 %
120mV
+5Vsb
0.0A
2.0A
± 5 %
± 1 %
100mV
Note: All data are subject to change without notice
*Maximum power: 300W
*+5V and +3.3V total output not exceed 180W
*+3.3V, +5V, and +12V total output power shall not exceed 280W
*+5V and +3.3V total output not exceed 180W
*+3.3V, +5V, and +12V total output power shall not exceed 280W
23181 Antonio Parkway, Rancho Santa Margarita CA 92688 U.S.A.
X
Telephone: (949) 766-9240
X
Fax: (949) 766-9241
E-mail: salesusa@fspgroup.com
X
Website: www.fspgroup.com
Rev. C 8-2003/DC