Panasonic PT-DX810 PT-DX810ELS User Manual

Product codes
PT-DX810ELS
Page of 15
S
P
E
C
F
I
L
E
PT-DX810S/DX810K/DX810LS/DX810LK
DLP
Projectors
As  of  July 2012
SFD12M009
1 1 / 1 5
Serial  connector
The  serial  connector  complies  with  RS-232C.  To  control  the  projector  from  a  personal  computer,  com-
mands  must  be  input  through  communication  software,  based  on  the  format  and  satisfying  the  commu-
nication  conditions  shown  below.
Basic  format
Transmission  from  the  computer  begins  with  STX,  then  the  ID,  command,  parameter,  and  ETX  are  sent
in  this  order.  Add  parameters  according  to  the  details  of  control.
Communication  conditions  (factory  setting)
Pin  assignments  and  signal  names
6
1
5
9
D-sub  9-pin  (female)  Serial  input
Description
NC
Send  data
Receive  data
Connected  internally
Ground
Signal  name
TXD
RXD
GND
No.
1
2
3
4
5
Description
NC
Connected  internally
Connected  internally
NC
Signal  name
CTS
RTS
No.
6
7
8
9
Pin  assignments  and  signal  names
9
5
1
6
D-sub  9-pin  (male)  Serial  output
Description
NC
Receive  data
Send  data
Connected  internally
Ground
Signal  name
RXD
TXD
GND
No.
1
2
3
4
5
Description
NC
Connected  internally
Connected  internally
NC
Signal  name
RTS
CTS
No.
6
7
8
9
CAUTION
• It  may  not  be  possible  to  send  or  receive  commands  for  about  10  to  60  seconds  when  the  lamp  is  first  turned  on.  If  this
occurs,  wait  for  60  seconds,  then  try  sending  or  receiving  again.
• When  sending  multiple  commands,  be  sure  to  wait  for  at  least  0.5  second  after  receiving  a  response  from  the  projector  before
sending  the  next  command.
• Additional  time  is  sometimes  required  for  response  due  to  processing  inside  the  projector.  Set  the  time-out  period  for  com-
mand  response  to  10  seconds  or  more.
• When  using  two  or  more  units:
1)  Set  different  IDs  for  each  unit.
2)  Designate  only  one  unit  as  RESPONSE  (ID  ALL)  ON  and  the  rest  as  RESPONSE  (ID  ALL)  OFF.
3)  Each  group  should  have  only  one  RESPONSE  (ID  GROUP)  ON  and  the  rest  should  be  RESPONSE  (ID  GROUP)  OFF.
Start
(1 byte)
End
(1 byte)
Colon
(1 byte)
Semicolon
(1 byte)
(2 byte)
ID designator
01 to 64: Address number
0A to 0Z: Group ID
ZZ: All units (ID ALL)
ID: 2 characters 
(2 bytes)
Parameters 
(undefined length)
Command
(3 bytes)
(Control and/or query commands)
STX
ETX
C1
P1 P2 ... Pn
C2
A
D
I1 I2
C3
:
 ; 
Signal  level
Synchronization  method
Baud  rate
Parity
Character  length
Stop  bit
X  parameter
S  parameter
RS-232C-compliant
Start-stop  synchronization
9,600  bps
None
8  bits
1  bit
None
None