Superior Essex 09-092-02 Leaflet

Page of 2
F-8
Premises 
Co
PP
er
Premises 
Fiber
o
sP 
Fiber
o
sP 
Com
Po
site
Centr
al 
oFF
iC
Co
PP
er
rDUP
/r
U
s o
sP 
Co
PP
er
bell 
o
sP 
Co
PP
er
o
sP 
Co
PP
er 
Wire
Cana
D
ian 
o
sP 
Co
PP
er
te
Chni
Cal 
in
Fo
Rev 1/12  Ed 11.0
Toll Free 
800.551.8948 | Fax 770.657.6807 | 
Specifications
Conductor
Solid annealed copper
Insulation
Dual insulation consisting of an inner layer of foamed, natural 
polyolefin over which is applied a solid (skin) layer of 
polyolefin colored in accordance with industry standards
Twisted Pairs
Individual insulated conductors; twisted into pairs with 
varying lay lengths; specific color combinations provide 
pair identification
≤ 25-Pair Core
Pairs are assembled into a cylindrical core
> 25-Pair Core
Cables larger than 25-pair are assembled into units,  
which are then used to assemble the core; units  
are identifiable using color-coded binders
Filling Compound
80°C ETPR compound, completely filling the interstices 
between the pairs and under the core wrap
Core Wrap
Non-hygroscopic, dielectric tape applied over the core
Shield
Corrugated, copolymer coated, 8 mil aluminum tape applied 
longitudinally with an overlap; flooded shield interfaces
Jacket
Black, polyethylene
Jacket Marking
Identifying information includes a telephone handset, 
cable code, pair count, AWG, date of manufacture  
and sequential length markings at 2 foot intervals
Standards Compliance
ANSI/ICEA S-84-608-2007
RDUP 7 CFR 1755.890 (PE-89)
RoHS-compliant
Electrical Specifications
Number of Pairs
Average Mutual 
Capacitance @ 1000 Hz 
nF/mile (nF/km)
Capacitance Unbalance 
Pair to Pair @ 1 kHz
Capacitance Unbalance  
Pair to Ground @ 1 kHz
Maximum Individual
pF @ 1 kft (pF @ 1 km)
Maximum RMS
pF @ 1 kft (pF @ 1 km)
Maximum Individual
pF @ 1 kft (pF @ 1 km)
Maximum Average 
pF @ 1 kft (pF @ 1 km)
12 or less
83 ± 7 (52 ± 4)
80 (145)
-
800 (2,625)
-
Over 12
83 ± 4 (52 ± 2)
80 (145)
25 (45)
800 (2,625)
175 (574)
Conductor Size  
AWG (mm)
Minimum Insulation 
Resistance @ 68°F (20°C) 
gigohm-mile (gigohm-km)
Maximum Average 
Attenuation* 
772 kHz @ 68°F (20°C) 
dB/kft (dB/km)
Maximum Conductor 
Resistance @ 68°F (20°C)
Ohms/sheath
mile (km)
DC Resistance Unbalance 
Maximum %
Dielectric Strength 
DC Potential – Volts
Average
Individual 
Pair
Conductor  
to Conductor
Conductor  
to Shield
19 (0.90)
1.0 (1.6)
3.2 (10.5)
45.0 (28.0)
1.5
5.0
4,500
10,000
22 (0.64)
1.0 (1.6)
4.5 (14.8)
91.0 (56.5)
1.5
5.0
3,600
10,000
24 (0.51)
1.0 (1.6)
5.6 (18.4)
144.0 (89.5)
1.5
5.0
3,000
10,000
26 (0.40)
1.0 (1.6)
7.0 (23.3)
232.0 (144.0)
1.5
5.0
2,400
10,000
*For cables with 12-pair or less, the maximum average attenuation may be increased by 10% over the values shown.
Minimum Near End Crosstalk (NEXT) 
@ 772 kHz
PSWUNEXT Mean (dB)
47
PSWUNEXT Worst Pair (dB)
42
Minimum Far End Crosstalk (FEXT)  
@ 772 kHz
Conductor Size (AWG)
19
22
24
26
PSELFEXT Mean (dB/kft)
51
49
49
47
PSELFEXT Worst Pair (dB/kft)
45
43
43
43
sealPiC®–FsF 
RDUP PE-89
Product Description
SEALPIC®-FSF Cables are designed for low risk direct burial or duct 
applications where protection from moisture is required and aluminum 
shielding is desired. SEALPIC-FSF may be used aerially, but must be 
attached to a support strand.
Applications
•  Low risk direct burial
•  Underground conduit
•  Lashed aerial
Features
Benefits
•  Twisted into pairs with varying  
lay lengths
•  Minimizes crosstalk
•  Core wrap
•  Provides thermal protection
•  Filled core
•  Moisture resistant
•  Fully flooded shield interfaces
•  Inhibits corrosion  
and water migration
•  Black, polyethylene jacket
•  Provides a tough, protective 
covering designed to withstand 
exposure to direct sunlight, 
atmospheric temperature 
changes and stresses expected 
in standard installations