Actebis Exsys EX-44095 PCI-Express 4S/1P Multi I/O card 15.06.1121 Leaflet

Product codes
15.06.1121
Page of 2
S
1
 
S
2
 
S
3
 
S
4
 
D
IS
 
P
W
R
 
If  you  are  ready  with  the  jumper  settings,  please  proceed  with  the  following  installation 
instructions.  Because  the  designs  of  computers  are  different,  only  general  installation 
instructions are given. Please refer your computer s reference manual whenever in doubt.  
1.  Turn off the power to your computer and any other connected peripherals. 
2.  Remove the mounting screws located at the rear and/or sides panels of your Com-
puter and gently slide the cover off. 
3.  Locate an available expansion slot and remove its covers from the rear panel of your 
computer. Make sure it is the right expansion slot for the card (see card description) 
4.  Align  the  card  with  the  expansion  slot,  and  then  gently  but  firmly,  insert  the  card. 
Make sure the card is seated and oriented correctly. Never insert the card by force! 
5.  Then connect the card with a screw to the rear panel of the computer case. 
6.  Gently replace your computer s cover and the mounting screws. 
HARDWARE INSTALLATION : 
EX
EX
EX
-
-
-
44095
44095
44095
 
 
 
English
English
English
 
 
 
EX
EX
EX
-
-
-
44095
44095
44095
 
 
 
English
English
English
 
 
 
Die  EX-44095  ist  eine  PCI-Express  Multi  I/O  Karte  mit einem Parallel Centronics EPP/
ECP Port und 4 seriellen FIFO 16C95x Ports, für den Anschluss von High-Speed seriel-
len RS-232 Peripherie Geräten (z.B. Terminal, Modem, Plotter usw.). Der serielle PCI-
Express Bus unterstützt dabei optimal die Leistung des schnellen 16C95x Chipsets mit 
128byte  FIFO  Cache.  Die  EX-44095  gewährleistet  so  eine  sichere  Datenübertragung 
und  exzellente  Performance  von  bis  zu  921KBaud/s  für  jedes  angeschlossene  Gerät! 
Sie unterstützt alle PCI-Express Slots  von x1 bis  x16.  Es ist  nicht möglich die I/O  Ad-
ressen und Interrupts manuell einzustellen, da die Einstellungen der Karte vom System 
(BIOS) und beim Installieren des Betriebssystems automatisch vorgenommen werden. 
Mit  dem  Jumper  JP1  können  Sie  vom  Standard  Quarz  (1.843MHz)  auf  den  schnellen 
(14.7456MHz) Quarz umschalten. Beachten Sie bitte falls Sie mit dem schnellen Quarz 
arbeiten,  dass  die  Peripheriegeräte  dies  auch  unterstützen.  Im  Gerätemanager  muss 
ausserdem die richtige Teilung (Divisor) & Geschwindigkeit manuell eingestellt werden. 
BESCHREIBUNG & TECHNISCHE DATEN : 
AUFBAU : 
Kompatibilität: 
PCI Express x1 bis x16 
Betriebs Systeme: 
WIN 9.x/ME/NT 4.0/2000/XP/Server 2003/Vista/(Linux vom OS) 
Anschlüsse: 
4 x 9 Pin Sub-D Stecker, 1x 25Pin parallel Buchse 
Lieferumfang: 
EX-44095, CD, Anleitung, 2x9 Pin Kabel, 1x25 Pin Kabel  
Zertifikate: 
CE 
FCC / RoHS / WEEE       DE97424562 / WHQL 
Windows 9x/ME/2000/XP & Vista:
 
After  starting  Windows  it  recognizes  a  new  PCI  Controller
 
and  open  the  hardware 
assistant. Please  choose manual  installation and put the  driver  CD  into  your  CD-Rom 
drive.  Now  enter  the  Path  "D:\IO\OXFORD\"  and  then  the  directory  of  your  operating 
system  95_98_ME 
2000 
XP32 
XP64 
Vista32  or  Vista64  into the box for 
the Path/Source and click at >next/continue<. Now Windows search for the drivers in 
the  specified  directory.  Follow  the  hardware  assistant  and  finish  the  installation.  If 
Windows recognizes  other  new  devices repeat  the  above  described  steps.  Attention! 
Restart Windows in any case after installing the drivers.  
CHECK THE INSTALLED DRIVER:
 
Click at Start<>Run< then enter  compmgmt.msc  and click at >OK<. In the windows 
that open select >Device  Manager<.  Under  Ports  (COM  and  LPT)  you should find 
one or more new  PCI  Ports  as sample  (COM3). If you see this or similar entries the 
card is installed correctly.  
CHANGE PORT NUMBER:
 
If  you  like  to  change  the  port  number  for  example  COM  3  to  COM5,  open  the  >Device 
Manager<  
click  at >COM3<,  >Settings<  and then >Advance<. There  you can change 
between COM 3 to 256.  
Windows Server 2000/2003:
 
After  starting  Windows  it  recognizes  a  new  PCI  Controller
 
and  open  the  hardware 
assistant. Please  choose manual  installation and put the  driver  CD  into  your  CD-Rom 
drive.  Now  enter  the  Path  "D:\IO\OXFORD\"  and  then  the  directory  of  your  operating 
system for Server 2000:  2000  and for Server 2003:  XP32  or  XP64  into the box 
for the Path/Source and click at >next/continue<. Now Windows search for the drivers 
in  the  specified  directory.  Follow  the  hardware  assistant  and  finish  the  installation.  If 
Windows recognizes  other  new  devices repeat  the  above  described  steps.  Attention! 
Restart Windows in any case after installing the drivers.  
CHECK THE INSTALLED DRIVER:
 
Click at Start<>Run< then enter  compmgmt.msc  and click at >OK<. In the windows 
that open select >Device  Manager<.  Under  Ports  (COM  and  LPT)  you should find 
one or more new  PCI  Ports  as sample  (COM3). If you see this or similar entries the 
card is installed correctly.  
CHANGE PORT NUMBER:
 
If  you  like  to  change  the  port  number  for  example  COM  3  to  COM5,  open  the  >Device 
Manager<  
click  at >COM3<,  >Settings<  and then >Advance<. There  you can change 
between COM 3 to 256.  
Windows NT 4.0:
 
Start Windows NT  and insert the driver  CD  into  your  CD-ROM drive (for  example  D:). 
Click at >Start< >Run< and enter  D:\IO\OXFORD\NT4\Install_Serial.exe" then  click 
>OK<.  Windows  NT  will  now  start  the  setup  program  and  install  the  driver.  Please 
Restart Windows NT after installing the drivers.  
CHECK THE INSTALLED DRIVER:
 
Click  at  >Start<  >Programs<  >Administrative  Tools[Common]<  >Windows  NT-
Diagnostics
<  then  click  at  >Resource<  >IRQ<.  Here  you  should  find  the  entry  09   
oxser   0    PCI 
. Then click at >I/O-Port< here you should see the entries  D400-D407  
oxser      0     PCI 
D800-D802    oxser     0    PCI  and  DC00-DC1F   oxser   0   PCI   
for  the  ports.  The  I/O  addresses  can  change  depends  which  system  and  card  is  in-
stalled. If you see these or similar entry's the card is installed correctly.  
LINUX:
 
There are no drivers available for Linux, but the card is supported by the most versions 
of  Linux.  Because  each  individual  distribution  and  kernel  version  of  Linux  is  different, 
sadly  we  cant  provide  a  installation  instruction.  Please  refer  to  the  installation  manual 
for  standard  IO  ports  from  your  Linux  version!  In  some  newer  versions  the  card  will 
even be installed automatically after starting Linux. 
DRIVER INSTALLATION : 
JP4: 
AUX5V  =  DC5V from J8, pc power supply cable is required 
AUX12V =  DC12V from J8, pc power supply cable is required  
PCI12V  =  DC12V from PCI Express (Factory setting), no cable   
For power over pc power supply J8 must be connected! 
Only if JP3 is set to PWR! The pin 9 from the serial port connector 
will be supplied with DC5V or DC12V. There are 3 sources depends 
on the jumper position of JP4.  
JP3: 
DIS 
=  The pin 9 is connected with the RI (Ring Indicator)    
signal as standard RS-232 definition (Factory setting). 
PWR 
=  The pin 9 is connected with a power either from PCI   
Express slot or from Aux Power connector (J8) The power source is 
controlled by JP4 jumper (see the following section). 
JUMPER SETTING & CONNECTORS
DB 9M: 
Pin 
Signal 
Pin 
Signal 
Pin 
Signal 
CDC 
DTR 
RTS 
RXD 
GROUND 
CTS 
TXD 
DSR 
RI 
Seriell 9 Pin D-SUB connector (S1 to S4): 
1 +5V 
2 GND 
3 GND 
4 +12V 
J8: 
AUX5V 
AUX12V 
PCI12V 
JUMPER EINSTELLUNG & ANSCHLÜSSE
JP1: 
Mit dem Jumper JP1 können sie zwischen zwei Clock Geschwindigkei-
ten wählen für Kompatibilität oder höhere Baudraten.  
LOW 
=  Die Clock ist auf 1.8432Mhz eingestellt für eine maximale   
Baudrate von 115.2KBaud. (Werkseinstellung). Diese    
Einstellung ist für die meisten Anwendungen optimal. 
HI 
=  Die Clock ist auf 14.7456Mhz eingestellt für die maximale   
Baudrate von 921.6KBaud.  
Bemerkung: Bei der Einstellung HI müssen sie im Gerätemanager von 
Windows bei den COM Port Einstellungen den Wert des Quarz automa-
tisch suchen und einstellen! 
JP2: 
Die Jumper auf JP2 bitte nicht verändern. Sie sind nur für Testzwecke 
im Werk!  
M2 
=  Jumper gesetzt 
M1 
=  Jumper gesetzt 
M0 
=  Jumper nicht gesetzt 
HI  LOW 
M2 
M1 
M0 
S1  9 Pin Stecker  
Seriell Anschluss 
S2  9 Pin Stecker  
Seriell Anschluss 
JP3  Power auf 9 Pin Stecker  
Ein / Aus 
JP2  UART Mode Einstellung   
(Nur für Testzwecke im Werk) 
JP1  Umschalter  
(für Datentransfer   
über 115.2KBaud) 
S1-  Interne 
S4  Serielle  
Anschlüsse 
JP4  Jumper für die Strom-  
quelle (Netzteil    
oder PCI-Express Bus) 
J8 
Anschluss für den  
Power vom Netzteil 
S4  9 Pin Stecker  
Seriell Anschluss 
S3  9 Pin Stecker  
Seriell Anschluss 
P1  25 Pin Buchse  
Parallel Anschluss 
J7  Interner Parallel Port   
für 25 Pin Kabel 
DB 25F: 
Pin 
Signal 
Pin 
Signal 
Pin 
Signal 
STROBE 
10 
ACKNOWLEDGE 
19 
GROUND 
DATA 0 
11 
BUSY 
20 
GROUND 
DATA 1 
12 
PAPER EMPTY 
21 
GROUND 
DATA 2 
13 
SELECT 
22 
GROUND 
DATA 3 
14 
AUTO FEED 
23 
GROUND 
DATA 4 
15 
ERROR 
24 
GROUND 
DATA 5 
16 
INIT 
25 
GROUND 
DATA 6 
17 
SELECT INPUT   
DATA 7 
18 
GROUND   
Parallel 25 female connector (P1): 
Bedienungsanleitung
Bedienungsanleitung
 
 
Vers. 3.1 / 06.06.07