Bosch EVF-1122S/126 EVF-1122S/126-PIB User Manual

Product codes
EVF-1122S/126-PIB
Page of 56
Electro-Voice EVF/EVH User Manual
15
Figure 5:
Typical response off the array axis of the two loudspeakers shown in Figure 4,
showing cancellations due to arrival-time differences
This effect is shown in the frequency-response of Figure 5. Given the dimensions of the typical compact 
loudspeaker systems and when they are clustered in close proximity to one another, the first several in-
terference nulls occur right in the middle of the vocal range. A frequency response with these ever-more-
closely spaced nulls is known as a “comb filter” response, after the visual appearance of the response.
3.0  Designing an EVF/EVH Cluster (cont’)
If one of the null frequencies is chosen and the horizontal polar response is measured, the result is shaped 
like the blue polar response in the center lower graph of Figure 6. In this view, the cluster axis points up 
(+X). Full output is achieved on this axis, since both signals arrive at the same time. But there are off-axis 
problems. While the overall coverage of the cluster is about 120° (6 dB down), two deep nulls occur at 
about 20° on either side of the cluster axis.
Figure 6:
Horizontal polar response (blue center 
plot) of two closely clustered 60° x 40° 
loudspeakers aimed 60° apart, showing 
the off-axis nulls at 1,250 Hz caused by 
multiple-source interference
(see text for more details)
NORMALIZED