Finally, another way to reduce interference is to apply signal delay of up to 8 milliseconds to one of the 
two systems. This requires a separate DSP (digital signal processor) drive to the delayed system. Figure 
10 shows the dramatic smoothing achieved at 1,250 Hz. Note that the systems are still close together as 
in Figure 6.
Figure 10:
Horizontal polar response (blue center plot) of two closely clustered 60° x 40° loudspeakers aimed 60° 
apart, showing the smoothing of multiple-source interference caused by a 3-ms delay to one loudspeaker
3.0  Designing an EVF/EVH Cluster (cont’)
In clusters with more than two systems, adjacent boxes are usually delayed. While the effect can be 
predicted with appropriate software (such as EASE 4.2), the actual delays are typically established in the 
field during system setup and commissioning, by ear and measurements.