Intel Server Board extended ATX E7500 LAN SWV2ATA User Manual

Product codes
SWV2ATA
Page of 6
All products, dates, and figures specified are preliminary based on current expectations, provided for planning purposes only, and are 
subject to change without notice. Availability in different channels may vary.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOP-
PEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S
TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EX-
PRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING
TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTU-
AL PROPERTY RIGHT. INTEL PRODUCTS ARE NOT INTENDED FOR USE IN MEDICAL, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS.
INTEL MAY MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME, WITHOUT NOTICE..
Intel, the Intel logo, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States
and other countries. 
*Other names and brands may be claimed as the property of others.
Copyright © 2002, Intel Corporation.
Intel Literature Center:  1-800-548-4725 
1102/SJ/DMW&LK/MD/PP/20K
ORDER NUMBER 298531-003
For the most current product information on Intel server building
blocks, visit:
www.intel.com/go/serverbuilder
Jumpers and Front-Panel Connectors
Jumpers
CMOS clear, password clear, BMC boot 
block write protect, BIOS recovery
Front-Panel Connectors Power LED, cool-fault LED, hard-drive 
access LED, system-fault LED, power/
sleep switch, server network connection
1 LED, server network connection 
2 LED, reset switch, and NMI switch
Mechanical
Server Board Style
SSI Thin E-Bay
Server Board Size
12" x 13"
Power Requirements 
+5V
2.6 A maximum continuous current
+5V Standby
1.5 A minimum continuous current
+12V
.5 A maximum continuous current
+3.3V
6.6 A maximum continuous current
–5V
0 A maximum continuous current
–12V
0 A maximum continuous current
Environment
Ambient Temperature
3
Operating (system): 10°C to 35°C; 
non-operating/storage (system): –40°C 
to +70°C ambient
Relative Humidity
Non-operating: 95%, non-condensing
at 30°C
Processor/Cache
One or two Intel
®
Xeon
processors with 512KB of integrated
Advanced Transfer Cache and 400 MHz or 533 MHz system bus;
for the latest processor support information, visit 
http://support.
intel.com/support/motherboards/server
System Memory
1
Memory Capacity
Six DIMM sockets for up to 12 GB of 
ECC DDR200/266 memory (256 MB to 
2 GB DIMMs supported; memory must 
be populated in pairs)
Memory Type
DDR200/266 registered SDRAM 72-bit 
ECC, 184-pin gold-plated DIMMs
DIMM Sizes
128 MB, 256 MB, 512 MB, 1 GB, 2 GB
Memory Voltage
2.5 V only
Error Detection
Corrects single-bit errors, detects double-
bit errors (using ECC memory), and supports
Intel
®
Single Device Data Correction (SDDC)
Integrated On-Board
Chipset
Intel
®
E7501 chipset
Ultra320 SCSI 
Adaptec* AIC-7902 Dual Channel: two 
Controller
2
Ultra320/LVD channels (connected via 
one internal 68-pin-wide connector and 
one 68-pin high-density external SCSI 
connector); maximum data transfer:
320 MB/sec on each Ultra320/LVD 
channel; supports HostRAID* (embedded 
SCSI striping/mirroring)
ATA/100 RAID
Promise* Technology PDC20277 
Controller
ATA/100 IDE RAID controller for two 
channels of ATA/100 IDE that can be 
configured into either RAID level 0 or 
RAID level 1; maximum data transfer:
100 MB/sec on each ATA/100 channel
Intel
®
Server 
Two Intel
®
PRO/1000 MT Server Network
Network Connections
Connections (Intel
®
82546EB Controller);
supports 10BASE-T, 100BASE-TX, and 
1000BASE-T, RJ45 output
Graphics
ATI* Rage* XL SVGA PCI video controller
with 8 MB of video memory
Super I/O Controller
National* PC87417
Input/Output
PCI
Triple-peer PCI buses, up to six slots on 
risers in a 2U system; bus A: 32-bit/
33MHz, bus B: 64-bit/66–100MHz,
bus C: 64-bit/66–100MHz
IDE
Two EIDE channels for a total of four IDE
devices (two on legacy connector,
two on high-density connector) 
USB
Two USB connectors (optional header 
for two more)
Serial Ports
External RJ45 serial, internal serial header
Floppy Controller 
1.44 MB, 2.88 MB, 3-mode support
Keyboard/Mouse  
PS/2, 8240A-compatible
Intel
® 
Server Management
Remote Management
Remote access to system status, logs,
configuration data, and utilities without 
the need for a remote-management card;
event filtering and alerting through 
proactive LAN and mobile devices 
System Monitoring 
System health indicators and corrective 
and Autorecovery
actions including automated power 
cycling, OS watchdog timer, and fault-
resilient booting
Server Troubleshooting Continuous health monitoring, text 
console redirection, and error logs
Serial over LAN
Serial data/console redirection over LAN
Supported Operating 
Microsoft* Windows* 2000,
Systems 
Red Hat* Linux*, Novell* NetWare*
Intelligent Platform 
Intelligent Platform Management 
Management Support
Interface (IPMI) 1.5
Fully Validated Operating Systems
Microsoft* Windows* 2000 Advanced Server, Red Hat* Linux* 8,
SuSE* Enterprise Server 8, and Novell* NetWare* 6
System BIOS
BIOS Type
8Mb Flash EEPROM with AMI* BIOS,
Multiboot BBS (BIOS Boot Specification) 
1.4-compliant
Special Features
Plug and Play, IDE drive autoconfigure,
SMBIOS 2.3, ECC/Parity support,
multilingual support, enabled for 
Rolling/Online BIOS updates
Configuration Utilities
System Setup Utility (SSU) for easy system
setup of BIOS utilities, Plug and Play
Safety Compliance
Canada 
UL/CUL 950-CSA 950 (UL Recognition 
Mark)
Europe/Russia
EN60950; CE Mark-EU Directive 
73/23/EEC; GOST-R Mark
International
IEC60950 
United States 
UL/CUL 950-CSA 950 (UL Recognition 
Mark)
EMI Verification
(based on board configured in a compatible
4
Intel host system)
Australia/New Zealand Verified to AS/NZS 3548, Class A (C-tick
Mark)
Canada
Verified to ICES-003, Class A
Europe
Verified to EN55022, Class A and 
EN55024 (CE Mark–EU Directive 
89/336/EEC)
International
Verified to CISPR-22/CISPR-24, Class A
Japan
Verified to CISPR-22/VCCI, Class A
Korea
RRL Certification to MIC Notices 1997-41
& 1997-42
Russia
Verified to GOSTR 29216-91, GOSTR 
50628-95 (GOST-R Mark)
Taiwan
Verified to BSMI 13438, Class A (DOC)
United States 
Verified to FCC, Class A
Recommended Configurations
and Order Codes
Suggested configurations for 1U and
2U systems using the Intel
® 
Server
Board SE7501WV2.
Intel
®
Server Board SE7501WV2 Specifications
SE7501WV2SCSI
KCW
BCW1USBPWB
AXX1U2URAIL
AXXCDFLOPPY or
AXXDVDFLOPPY
ACWBEZBLACK
AXXRJ45DB92
FXX2DRVCARBLK
TRM5RISER02
FCWCHASSISKT
FCWELECTKT
SRCZCR
PWLA8490XTL
AXX2ICMBKIT
SE7501WV2ATA
KCW
BCW1UABPWB
AXX1U2URAIL
AXXCDFLOPPY or
AXXDVDFLOPPY
ACWBEZBLACK
AXXRJ45DB92
FXX2DRVCARBLK
TRM5RISER02
FCWCHASSISKT
FCWELECTKT
PWLA8490XTL
AXX2ICMBKIT
SE7501WV2SCSI
KSW (hot swap
power) or KSW480
(fixed power)
Included
AXX2PSMODL500
AXX1U2URAIL
AXXCDFLOPPY or
AXXDVDFLOPPY
ASWBEZBLACK
AXXRJ45DB92
FXX2DRVCARBLK
ASWTAPECABLE
ASWFAN
TRL5RISER02 
FSWCHASSISKT
FSWELECTKT
SRCZCR
PWLA8490XTL
AXX2ICMBKIT
Included 
SE7501WV2SKU02
Included (KSW)
Included
AXX2PSMODL500
AXX1U2URAIL
CD/Floppy Included
ASWBEZBLACK
AXXRJ45DB92
FXX2DRVCARBLK
ASWTAPECABLE
Included 
TRL5RISER02 
FSWCHASSISKT
FSWELECTKT
SRCZCR
PWLA8490XTL
AXX2ICMBKIT
SE7501WV2ATA
Reference Chassis
only
5
AXXRJ45DB9
TRL5RISER02 
PWLA8490XTL
AXX2ICMBKIT
1U System with
Integrated SCSI
1U System with
Integrated
ATA/100 RAID
Building Block
Platform
2U System with
Integrated
ATA/100 RAID
Intel
®
Server Board SE7501WV2
Pre-Integrated Platform
Intel
®
Server Chassis SR1300 
(1U rack)
5
Intel
®
Server Chassis SR2300 
(2U rack)
5
Chassis Backplane (required)
Redundant Power Module 
Sliding Rails 
CD-ROM or DVD-ROM/Floppy
Module 
Locking Bezel (black)
Serial Cable Kit (RJ45 to DB9  
& 2U rear serial port) 
Additional Drive Carriers (10) 
Tape-Drive I/O Cable and 
Tape-Drive Power Cable 
Single-Fan Upgrade for 
Redundant Cooling 
5V Riser 
Chassis Spares Kit
Electrical Spares Kit
Intel
®
RAID Controller 
SRCZCR (modular ROMB)
6
Intel
®
PRO/1000 MT Server 
Adapter (low-profile)
6
ICMB Board Assembly (optional)
1
See 
http://support.intel.com
for a list of validated memory.
2
The Server Board SE7501WV2 is modular ROMB (RAID On 
MotherBoard) ready. Please visit 
http://www.intel.com/go/
serverbuilder
for details.
3
Environmental ambient temperature is the system-intake 
measurement for an Intel
®
Server Board SE7501WV2 installed in 
an Intel
®
Server Chassis SR2300.
4
Compatible host system denotes the system(s) with which Intel 
tested the board and found it compliant.
5
See 
http://support.intel.com
for a complete list of Intel and third-
party-compatible chassis.
6
See 
http://support.intel.com
for a complete list of validated 
Intel and third-party adapter cards.
Intel
®
SE7501WV2-based Systems
2U System with Integrated SCSI
D33025