times their rated power for short durations. This
ensures extra reliability under extreme conditions,
leading to greater customer satisfaction, longer
operating life, and much less chance of failure or
performance deterioration.
Safety
acc. to EN 60065
Emergency
acc. to EN 54‑24
 
acc. to EN 60849
 
acc. to BS 5839‑8
Water and dust protection
acc. to EN 60529 IP 65
Wind‑force
Acc. to NEN 6702:2007 + A1:
2008, Bft11
Region
Certification
Poland
CNBOP
Europe
CPD
Installation/configuration notes
The column loudspeakers can be wall mounted using
the swivel wall bracket standard supplied, or directly
onto a floor stand LBC 1259/01 with an M10 threaded
bolt without additional accessories. The bracket is
attached on a slider, which can be placed and secured
in any desired position along the rear of the enclosure.
Standard supplied with 2 m connection cable, but
these can be replaced during installation with any
other type of connection cable.
The connection cable is fed out through a cable gland
(PG 20) in the top rear of the enclosure. For loop
through connection, a second hole (covered as
standard supplied) is provided.
450mm
17.7"
96mm
3.8"
84mm
3.3"
100mm
3.94"
LA1-UM20E-1 Dimensions mm (in)
750mm
29.5"
96mm
3.8"
84mm
3.3"
100mm
3.94"
LA1-UM40E-1 Dimensions mm (in)
2 | LA1‑UMx0E‑1 Metal Column Loudspeakers