Bosch ISC-PDL1-W18G User Manual

Page of 5
 
Intrusion Alarm Systems | ISC‑PDL1‑W18x Professional Series TriTech Detectors
ISC‑PDL1‑W18x Professional Series
TriTech Detectors
 
www.boschsecurity.com
 
 
 
u
18 m x 25 m (60 ft x 80 ft) coverage, field selectable
to 8 m x 10 m (25 ft x 33 ft)
u
EN50131-2-4 Grade 2 compliant
u
Sensor data fusion technology
u
Tri-focus optics technology
u
Range adaptive radar
The ISC-PDL1-W18x Professional Series TriTech
Detectors are exceptionally suited for commercial
indoor applications. Sensor data fusion technology
ensures that the detectors send alarm conditions
based on precise information. Tri-focus optics
eliminate coverage gaps and respond efficiently to
intruders. The powerful combination of unique
features in the Professional Series delivers superior
catch performance and virtually eliminates false
alarms.
The self-locking two-piece enclosure, built-in bubble
level, flexible mounting height, and three optional
mounting brackets simplify installation and reduce
service time.
Functions
Sensor Data Fusion Technology
Sensor data fusion technology is a unique feature that
uses a sophisticated software algorithm to gather
signals from five sensors: two pyroelectric sensors,
range adaptive radar, a room temperature sensor, and
a white light level sensor. The microcontroller analyzes
and compares the sensor data to make the most
intelligent alarm decisions in the security industry.
Tri-focus Optics Technology
Tri-focus optics technology uses optics with three
specific focal lengths: long-range coverage, middle-
range coverage, and short-range coverage. The
detector applies the three focal lengths to 86
detection zones, which combine to make 11 solid
curtains of detection. Tri-focus optics technology also
includes two pyroelectric sensors, which deliver twice
the standard optical gain. The sensors process
multiple signals to deliver precise performance
virtually free of false alarms.
Range Adaptive Radar
The microwave transceiver automatically adjusts its
detection thresholds based on input from the PIR
sensors. Integrating the target audience distance
information from the PIR significantly reduces false
alarms from the microwave Doppler radar.