Panduit NCMHF2 Leaflet

Page of 2
w w w. p a n d u i t . c o m
SPECIFICATION SHEET
NetManager
Horizontal Cable Managers
Dimensions:
NCMH2: 3.47"H x 19.0"W x 9.75"D (88.1 x 482.6 x 247.7mm)
NCMHF2: 3.47"H x 19.0"W x 3.75"D (88.1 x 482.6 x 95.3mm)
NCMHF1: 1.72"H x 19.0"W x 3.75"D (43.7 x 482.6 x 95.3mm)
Mounting option:
Mounts to standard EIA 19" rack or 23" rack with optional
extender bracket
Packaging:
Cable management panels include hinged front cover, snap-on rear
cover and mounting hardware
Finger spacing:
3/8" spacing between fingers
Bend radius:
1/2" bend radius for fingers, transitions and pass throughs on front
control
3/8" bend radius for fingers on rear
k e y   f e a t u r e s   a n d   b e n e f i t s
a p p l i c a t i o n s
t e c h n i c a l   i n f o r m a t i o n
s p e c i f i c a t i o n s
Horizontal cable managers shall be capable of
managing copper or fiber cables. They shall be
molded out of plastic and incorporate bend radius
control throughout the fingers, pass through holes,
and transitions between horizontal and vertical
pathways. Front hinged cover shall open 180° 
in up or down position. They shall mount to 
any standard EIA 19" rack.
Integral bend radius
Maintains cable bend radii in all cable pathways for
high performance copper and fiber applications
Curved fingers
Separates and organizes Category 5e and Category 6
cable for simple moves, adds and changes
Cable pass through holes
Provides ease of installation and cable maintenance
Integral wire retainers
Holds cable in place for easy moves, adds and changes
Lightweight plastic 
Provides durability and easy installation
construction
Hinged front cover
Opens 180° up or down to allow hands-free access
to cable
Designed for Category 5e, Category 6 
and fiber cables, the Panduit
®
NetManager
Horizontal Cable Managers provide a 
cost effective solution that organizes, 
manages, and protects network cabling in
telecommunication rooms and data centers.
Finger spacing organizes cable as they exit 
the patch panel and bend radius control helps 
protect cable from kinks, snags and crushing,
ensuring system performance and reliability.
When used with Panduit
®
Mini-Com
®
or
QuickNet
®
Patch Panels, Panduit patch 
cords, vertical managers, and racks, the 
user receives a complete end-to-end solution
that satisfies functional requirements and
showcases the network cabling.
2 Rack Space Panel, Front and Rear
3" x 3" front and
2" x 5" rear
NCMH2
2 Rack Space Panel, Front Only
3" x 3" front:
NCMHF2
1 Rack Space Panel, Front Only
1.5" x 3" front:
NCMHF1
Accessories
Extender bracket, 1 RU:
PEB1
Extender bracket, 2 RU:
PEB2
(for 23" rack mounting)
Standard 2 Post Racks – 7 Foot
3" channel
19" mount:
CMR19X84
19" mount:
CMR19X84S
19" mount:
R2P79
19" mount:
R2P^
19" mount:
R2P48
6" channel
19" mount:
R2P6S
^Add suffix 96 to the end of the part number
for 8 foot versions.
4 Post Racks, 19" Mount – 7 Foot
23" deep:
R4P23*^
30" deep:
R4P*^
36" deep:
R4P36*^
42" deep:
R4P42*^
*Add “CN” for Cage Nut Rails
^Add suffix 96 to the end of the part number
for 8 foot versions.
NetRunner
Vertical Cable Managers
Front and rear
22 RU, 4" x 5":
WMPV22E
45 RU, 4" x 5":
WMPV45E
45 RU, 6" x 6":
WMPVHC45E
Front only
22 RU, 4" x 5":
WMPVF22E
45 RU, 4" x 5":
WMPVF45E
45 RU, 6" x 6":
WMPVHCF45E
NetRunner
High Capacity Vertical
Cable Managers
Front and rear
45 RU, 6" x 6":
NRV6
45 RU, 10" x 6":
NRV10
45 RU, 12" x 6":
NRV12
Front only
45 RU, 6" x 6":
NRVF6
45 RU, 10" x 6":
NRVF10
45 RU, 12" x 6":
NRVF12
Doors
6" wide:
NRD6
10" wide:
NRD10
12" wide:
NRD12
PatchRunner
Vertical Cable Managers
7 Foot ^
Front and rear
45 RU 6" wide:
PRV6
45 RU 8" wide:
PRV8
45 RU 10" wide:
PRV10
45 RU 12" wide:
PRV12
45 RU 15" wide:
PRV15
Front only
45 RU 6" wide:
PRVF6
45 RU 8" wide:
PRVF8
45 RU 10" wide:
PRVF10
45 RU 12" wide:
PRVF12
45 RU 15" wide:
PRVF15
Dual Hinged Doors 7 Foot ^
6" wide:
PRD6
8" wide:
PRD8
10" wide:
PRD10
12" wide:
PRD12
15" wide:
PRD15
Single Hinged Doors
6" wide:
PRSHD6
8" wide:
PRSHD8
12" wide:
PRSHD12
^Add suffix 96 to the end of the part number
for 8 foot versions.