Uniwide UniServer 1522ES 008-00135B Manual

Product codes
008-00135B
Page of 102
 
75
 
5.2.3.2.3    Creating s Second IM or IME Volume 
The LSI Logic SAS controllers allow you to configure two IM or IME volumes. If one volume is already 
configured, and if there are available disk drives, there are two ways to add a second volume. 
 
The first is as follows: 
① 
In the configuration utility, select an adapter from the Adapter List. Select the RAID Properties     
option. This will display the current volume 
② 
Press C to create a new volume. 
③ 
Continue with step 4 of the IM or IME creation procedure in the previous section to create a   
second volume. 
 
The other way in which to add a second volume is as follows: 
① 
On the Adapter List screen, use the arrow keys to select an LSI Logic SAS adapter. 
② 
Press Enter to go to the Adapter Properties screen, shown in Figure. 
③ 
On the Adapter Properties screen, use the arrow keys to select RAID Properties and press Enter. 
④ 
with step 4 of the IM or IME creation procedure in the previous section to create a second volume. 
 
 
5.2.3.2.4  Managing Hot Spares 
You can create one global hot spare disk to protect the one or two IM/IME volumes defined on a SAS controller. 
Usually, you create the global hot spare at the same time you create the IM/IME volume.   
Follow these steps to add a global hot spare disk later for the existing IM/IME volumes on the controller:   
① 
On the View Array screen, select Manage Array. 
② 
Select Manage Hot Spare on the Manage Array screen, shown in below Figure.