INTERNET CONTROL
OPTIONAL
7,10 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
4,40 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
Down to
-20 ºC
 in
cooling mode
OUTDOOR
TEMPERATURE
Down to
-15 ºC
 in
heating mode
OUTDOOR
TEMPERATURE
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Recommended fuse for the indoor 3A.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
Easy
control
by BMS
CONNECTIVITY
Complete line-up with high efficiency even at -20°C
This wall-mounted air conditioner is especially designed for professional applications such as computer rooms 
where cooling inside the room is necessary even when the outside temperature is low. Furthermore this air 
conditioner has an automatic changeover system, in order to maintain the inside temperature even when sharp 
outside temperature changes occur.
WALL MOUNTED 
PROFESSIONAL
INVERTER -20°C
E
nergy 
saving
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
· SERVER ROOM 
SOLUTION WITH THE 
HIGHEST EFFICIENCY OF 
THE MARKET
· 24/7 OPERA
TION
KIT
KIT-E9-PKEA
KIT-E12-PKEA
KIT-E15-PKEA
KIT-E18-PKEA
Indoor
CS-E9PKEA
CS-E12PKEA
CS-E15PKEA
CS-E18PKEA
Outdoor
CU-E9PKEA
CU-E12PKEA
CU-E15PKEA
CU-E18PKEA
Cooling capacity
Nominal (Min-Max)
kW
2,50 (0,85-3,00)
3,50 (0,85-4,00)
4,20 (0,98-5,00)
5,00 (0,98-6,00)
Nominal (Min-Max)
kCal/h
2.150 (730-2.580)
3.010 (730-3.440)
3.610 (840-4.300)
4.300 (840-5.160)
Cooling capacity at -10°C
Nominal
kW
2,63
3,69
5,04
6,00
EER at -10°C
Nominal
Energy Saving
7,19
5,96
6,01
6,00
Cooling capacity at -20°C
Nominal
kW
2,61
3,66
4,06
5,82
EER at -20°C
Nominal
Energy Saving
6,71
5,56
4,39
5,39
SEER
Nominal
Energy Saving 7,1 i
6,7 i
6,3 i
6,9 i
Pdesign
kW
2,5
3,5
4,2
5,0
Power input Cooling
Nominal (Min-Max)
kW
0,515 (0,170-0,710)
0,870 (0,170-1,120)
1,200 (0,280-1,580)
1,440 (0,280-1,990)
Annual electricity consumption (cooling) 
1)
kWh/a
123
183
233
254
Heating capacity
Nominal (Min-Max)
kW
3,40 (0,85-5,40)
4,00 (0,85-6,60)
5,40 (0,98-7,10)
5,80 (0,98-8,00)
Nominal (Min-Max)
kCal/h
2.920 (730-4.640)
3.440 (730-5.680)
4.640 (840-6.110)
4.990 (840-6.880)
Heating capacity at -7°C
Nominal
kW
3,33
4,07
4,10
4,98
SCOP
Nominal
Energy Saving 4,4 h
4,1 h
3,9 a
4,2 h
Pdesign at -10 ºC
kW
2,8
3,6
3,6
4,4
Power input Heating
Nominal (Min-Max)
kW
0,700 (0,165-1,310)
0,920 (0,165-1,820)
1,440 (0,340-2,190)
1,520 (0,340-2,570)
Annual electricity consumption (heating) 
1)
kWh/a
891
1.229
1.292
1.467
Indoor Unit
Power source
V
230
230
230
230
Recommended Fuse
A
16
16
16
16
Connection indoor / outdoor
mm
4 x 1,5
4 x 1,5
4 x 1,5
4 x 2,5
Current (Nominal) 
Cooling / Heating
A
2,5 / 3,3
4,0 / 4,2
5,4 / 6,5
6,4 / 6,8
Max. Current
A
7,8
8,4
9,6
11,3
Air Volume
Cooling / Heating
m³/h
798 / 876
816 / 882
846 / 900
1074 / 1158
Moisture removal volume
l/h
1,5
2,0
2,4
2,8
Sound pressure level 
2)
Cooling (Hi / Lo / S-Lo) dB(A)
39 / 26 / 23
42 / 29 / 26
43 / 32 / 29
44 / 37 / 34
Heating (Hi / Lo / S-Lo) dB(A)
40 / 27 / 24
42 / 33 / 30
43 / 35 / 29
44 / 37 / 34
Sound power level
Cooling / Heating (Hi)
dB
55 / 56
58 / 58
59 / 59
60 / 60
Dimensions
H x W x D
mm
295 x 870 x 255
295 x 870 x 255
295 x 870 x 255
295 x 1.070 x 255
Net weight
kg
10
10
10
13
Air purifier filter
Outdoor Unit
Air Volume
Cooling / Heating
m³/h
1.878 / 1.782
1.974 / 1.926
2.052 / 1.980
2.352 / 2.274
Sound pressure level 
2)
Cooling / Heating (Hi)
dB(A)
46 / 47
48 / 50
46 / 46
47 / 47
Sound power level
Cooling / Heating (Hi)
dB
61 / 62
63 / 65
61 / 61
61 / 61
Dimensions 
3)
H x W x D
mm
622 x 824 x 299
622 x 824 x 299
695 x 875 x 320
695 x 875 x 320
Net weight
kg
36
36
45
46
Piping connections
Liquid pipe / Gas pipe
inch (mm)
1/4" (6,35) / 3/8" (9,52) 
1/4" (6,35) / 3/8" (9,52) 
1/4" (6,35) / 1/2" (12,70)
1/4" (6,35) / 1/2" (12,70)
Refrigerant loading
R410A
kg
1.100
1.100
1,060
1,240
Elevation difference (in/out) 
4)
Max
m
5
5
15
15
Piping length
Min / Max
m
3-15
3-15
3-15
3-20
Precharge length
Max
m
7,5
7,5
7,5
7,5
Additional charge
g/m
20
20
20
20
Operating range
Cooling Min / Max
°C
-20 / +43
-20 / +43
-20 / +43
-20 / +43
Heating Min / Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24