Panasonic CS-E9QKEW User Manual

Page of 92
Outdoor Units for Free Multi combinations
CU-2E15PBE
CU-2E18PBE
CU-3E18PBE
CU-4E23PBE
CU-4E27PBE
CU-5E34PBE
Outdoor Unit //Inverter+
3,2 to 5,6 kW
3,2 to 6,4 kW
4,5 to 9,0 kW
4,5 to 11,0 kW
4,5 to 13,6 kW
4,5 to 17,5 kW
Unit
CU-2E15PBE
CU-2E18PBE
CU-3E18PBE
CU-4E23PBE
CU-4E27PBE
CU-5E34PBE
Cooling capacity
Nominal (Min - Max)
kW
4,50 (1,50 - 5,20)
5,20 (1,50 - 5,40)
5,20 (1,80-7,30)
6,80 (1,90 - 8,80)
8,00 (3,00 - 9,20)
10,00 (2,9 - 11,5)
Nominal (Min - Max)
kCal/h
3.870 (1.290 - 4.470)
4.472 (1.290 - 4.644)
4.470 (1.548-6.278)
5.850 (1.630 - 7.570)
6.880 (2.580 - 7.912)
8.600 (2.494 - 9.890)
SEER
Nominal
W/W
6,50 i
6,50 i
7,00 i
7,00 i
7,00 i
6,50 i
Pdesign (cooling)
4,50
5,20
5,20
6,80
8,00
10,00
Power input cooling
Nominal (Min - Max)
kW
1,230 (0,250 - 1,520)
1,490 (0,250 - 1,540)
1,210 (0,360-2,180)
1,680 (0,340 - 2,470)
1,980 (0,530 - 2,870)
2,860 (0,550 - 3,860)
Annual electricity consumption (cooling)
kW
242
280
260
340
400
538
Heating capacity
Nominal (Min - Max)
kWh/a
5,40 (1,10 - 7,00)
5,60 (1,10 - 7,20)
6,80 (1,60-8,30) 
8,50 (3,00 - 10,60)
9,40 (4,20 - 10,60)
12,00 (3,40 - 14,50)
Nominal (Min - Max)
kCal/h
4.640 (950 - 6.020)
4.820 (950 - 6.190)
5.850 (1.200-7.140)
7.130 (2.580 - 9.120)
8.084 (3.612 - 9.116)
10.320 (2.924 - 12.470)
SCOP
Nominal
W/W
4,00 h
4,00 h
4,00 h
4,00 h
4,00 h
4,00 h
Pdesign at -10°C
kW
4,00
3,80
4,80
5,50
8,00
10,00
Power input heating
Nominal (Min - Max)
kW
1,170 (0,210 - 1,670)
1,300 (0,240 - 1,700)
1,450 (0,320 - 2,110)
1,850 (0,580 - 2,600)
2,080 (0,700 - 3,060)
2,860 (0,530 - 4,240)
Annual electricity consumption (heating)
kWh/a
1.400
1.330
1.680
1.925
2.800
3.500
Current
Cooling
A
5,75
7,10
5,30
7,50
9,40
13,20
Heating
A
5,20
5,35
6,70
8,80
9,80
13,40
Power source
V
230
230
230
230
230
230
Recommended fuse
A
16
16
16
20
20
25
Recommended power cable section
mm²
1,5
1,5
2,5
2,5
2,5
3,5
Sound pressure level¹
Cooling / Heating (Hi)
dB(A)
47 / 49
49 / 51
46 / 47
48 / 49
51 / 52
53 / 54
Sound power level
Cooling / Heating (Hi)
dB
62 / 64
64 / 66
60 / 61
62 / 63
67 / 68
69 / 70
Dimensions
H x W x D
mm
619 x 824 +70 x 299
619 x 824 x 229
795 x 875 (+95) x 320
795 x 875 (+95) x 320
999 x 940 x 340
999 x 940 x 340
Net weight
kg
39
39
71
72
80
81
Piping connections
Liquid pipe
inch (mm) 1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
Gas pipe
inch (mm)  3/8 (9,52)
 3/8 (9,52)
 3/8 (9,52)
 3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Refrigerant loading
R410A
kg
1,40
1,40
2,64
2,64
3,4
3,4
Elevation diff. (in/out)
Max
m
10
10
15
15
15
15
Piping length total
Min / Max
m
3 / 30
3 / 30
3 / 50
60
80
80
Piping length to one unit Min / Max
m
3 / 20
3 / 20
3 / 25
3 / 25
3 / 25
3 / 25
Precharge length
m (Max)
20
20
30
30
45
45
Additional charge
g/m
15
15
20
20
20
20
Operating range
Cooling Min/Max
°C
-10 / +46
-10 / +46
-10 / +46
-10 / +46
-10 / +46
-10 / +46
Heating Min/Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24
-15 / +24
-15 / +24
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
4,00 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
E
nergy 
saving
Down to
-15 ºC
 in
heating mode
OUTDOOR
TEMPERATURE
7,00 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
ROTARY 
INVERTER COMPRESSOR
5 year
compressor
warranty
Low Static Pressure Hide Away 
2,5 kW
3,2 kW
5,0 kW
Indoor
CS-E9PD3EA
CS-E12PD3EA
CS-ME18PD3EA
Cooling capacity
Nominal
kW / kCal/h
2,50 / 2.150
3,4 / 2.920
5,00 / 4.300
Heating capacity
Nominal
kW / kCal/h
3,20 / 2.752
4,00 / 3.440
6,80 / 5.850
Connection
mm²
4 x 1,5 to 2,5
4 x 1,5 to 2,5
4 x 1,5
External static pressure²
S-Hi / Hi / Me / Lo
Pa
110 / 60 / 30 / 20
80 / 50 / 25 / 10
34 / 78 (3,47 / 7,95)
Air volume
Cooling / Heating
m³/h
414 / 486
540 / 630
624 / 528 / 444
Sound pressure level¹
Cooling (Hi / Lo / S-Lo) dB(A)
33 / 27 / 24
33 / 27 / 24
27 / 30 / 41
Heating (Hi / Lo / S-Lo) dB(A)
35 / 28 / 25
35 / 28 / 25
29 / 32 / 41
Sound power level
Cooling (Hi)
dB
49
49
57
Heating (Hi)
dB
51
51
57
Dimensions
H x W x D
mm
235 x 750 x 370
285 x 750 x 370
285 x 750 (+65) x 370
Net weight
kg
17
17
18
Piping connections
Liquid / Gas pipe
Inch (mm)
1/4 (6,35
1/4 (6,35)
1/4 (6,35)
Liquid / Gas pipe
Inch (mm)
3/8 (9,52)
3/8 (9,52)
1/2 (12,70)
INTERNET CONTROL READY and EASY 
CONTROL by BMS: Optional only for 
E9 and E12.
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Easy
control
by BMS
CONNECTIVITY
Include on the 
indoor unit
Possible
to use on
R22 pipings
R22 RENEWAL
73
DOMESTIC
NEW