Panasonic CS-E12QKEW User Manual

Page of 92
New UE series inverter powerful and efficient.
WALL MOUNTED UE TYPE 
STANDARD INVERTER
E
nergy 
saving
6,50 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
4,30 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
SUPER QUIET
Silent air
22 dB
Kit
KIT-UE9-QKE
KIT-UE12-QKE
KIT-UE18-QKE
Indoor
CS-UE9QKE
CS-UE12QKE
CS-UE18QKE
Outdoor
CU-UE9QKE
CU-UE12QKE
CU-UE18QKE
Cooling capacity
Nominal (Min - Max)
kW
2,50 (0,85 - 3,00)
3,50 (0,85 - 3,90)
5,00 (0,98 - 5,60)
Nominal (Min - Max)
kCal/h
2.150 (730 - 2.580)
3.010 (730 - 3.350)
4.300 (840 - 4820)
SEER
Nominal
Energy Saving 5,60 h
5,60 h
6,50 i
Pdesign (cooling)
2,5
3,5
5,0
Power input cooling
Nominal (Min - Max)
kW
0,720 (0,250 - 1,020)
1,090 (0,255 - 1,280)
1,540 (0,285 - 1,750)
Annual electricity consumption (cooling) 
1)
kWh/a
156
219
269
Heating capacity
Nominal (Min - Max)
kW
3,30 (0,80 - 4,10)
4,00 (0,80 - 5,10)
5,40 (0,98 - 7,70)
Nominal (Min - Max)
kCal/h
2.840 (690 - 3.530)
3.440 (690 - 4.390)
4.640 (840 - 6.620)
Heating capacity at -7°C
Nominal
kW
2,66
3,2
4,79
SCOP
Nominal
Energy Saving 3,80 a
3,80 a
4,30 h
Pdesign at -10 °C
kW
1,9
2,4
4,0
Power input heating
Nominal (Min - Max)
kW
0,860 (0,175 - 1,180)
1,100 (0,200 - 1,470)
1,470 (0,350 - 2,300)
Annual electricity consumption (heating) 
1)
kWh/a
700
884
1.302
Indoor Unit
Power source
V
230
230
230
Recommended fuse
A
16
16
16
Recommended power cable section
mm²
1,5
1,5
2,5
Connection indoor / outdoor
mm²
4 x 1,5
4 x 1,5
4 x 1,5
Current (Nominal)
Cooling / Heating
A
3,20 / 3,80
4,80 / 4,90
6,90 / 6,70
Maximum current
A
5,3
6,7
10,1
Air volume
Cooling / Heating
m³/h
702 / 768
738 / 768
978 / 1.074
Moisture removal volume
l/h
1,5
2
2,8
Sound pressure level 
2)
Cooling (Hi / Lo / Q-Lo) dB(A)
41 / 26 / 22
42 / 30 / 22
44 / 37 / 
Heating (Hi / Lo / Q-Lo) dB(A)
41 / 27 / 25
42 / 33 / 25
44 / 37 / 
Sound power level
Cooling (Hi)
dB
57
58
60
Heating (Hi)
dB
57
58
60
Dimensions
H x W x D
mm
290 x 870 x 214
290 x 870 x 214
290 x 1.070 x 240
Net weight
kg
9
9
12
Air purifier filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Outdoor Unit
Air volume
Cooling / Heating
m³/h
1.926 / 1.872
1.860 / 1.860
2.064 / 2.040
Sound pressure level 
2)
Cooling (Hi)
dB(A)
47
48
48
Heating (Hi)
dB(A)
48
50
49
Sound power level
Cooling (Hi)
dB
62
63
64
Heating (Hi)
dB
63
65
63
Dimensions 
3)
H x W x D
mm
542 x 780 x 289
542 x 780 x 289
622 x 824 x 299
Net weight
kg
31
33
38
Piping connections
Liquid pipe
inch (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
Gas pipe
inch (mm)
3/8 (9,52)
3/8 (9,52) 
1/2 (12,70)
Refrigerant loading
R410A
kg
0,85
1,00
1,43
Elevation difference (in/out) 
4)
Max
m
15
15
15
Piping length
Min / Max
m
3 / 15
3 / 15
3 / 15
Precharge length
Max
m
7,5
7,5
7,5
Additional gas
g/m
20
20
20
Operating range
Cooling Min / Max
°C
5 / +43
5 / +43
5 / +43
Heating Min / Max
°C
-10 / +24
-10 / +24
-10 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with QKE units.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. Q-Lo: The lowest fan speed. Lo: The second lowest fan speed (the lowest fan speed for UE18) 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
SEER and SCOP: For KIT-UE18-QKE. SUPER QUIET: For UE9 and UE12.
Prevention
allergen filter
ANTI BACTERIAL 
FILTER
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty