YE Inverter models are powerful and efficient.
WALL MOUNTED YE TYPE 
STANDARD INVERTER
E
nergy 
saving
5,60 A+
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
3,80 A
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
SUPER QUIET
Silent air
22 dB
Kit
KIT-YE9-QKE
KIT-YE12-QKE
Indoor
CS-YE9QKE
CS-YE12QKE
Outdoor
CU-YE9QKE
CU-YE12QKE
Cooling capacity
Nominal (Min - Max)
kW
2,50 (0,85 - 3,00)
3,50 (0,85 - 3,90)
Nominal (Min - Max)
kCal/h
2.150 (730 - 2.580)
3.010 (730 - 3.350)
SEER
Nominal
Energy Saving 5,60 h
5,60 h
Pdesign (cooling)
2,5
3,5
Power input cooling
Nominal (Min - Max)
kW
0,720 (0,250 - 1,020)
1,090 (0,255 - 1,280)
Annual electricity consumption (cooling) 
1)
kWh/a
156
219
Heating capacity
Nominal (Min - Max)
kW
3,30 (0,80 - 4,10)
4,00 (0,80 - 5,10)
Nominal (Min - Max)
kCal/h
2.840 (690 - 3.530)
3.440 (690 - 4.390)
Heating capacity at -7°C
Nominal
kW
2,66
3,2
SCOP
Nominal
Energy Saving 3,80 a
3,80 a
Pdesign at -10 °C
kW
1,9
2,4
Power input heating
Nominal (Min - Max)
kW
0,860 (0,195 - 1,180)
1,100 (0,200 - 1,470)
Annual electricity consumption (heating) 
1)
kWh/a
700
884
Indoor Unit
Power source
V
230
230
Recommended fuse
A
16
16
Recommended power cable section
mm²
1,5
1,5
Connection indoor / outdoor
mm²
4 x 1,5
4 x 1,5
Current (Nominal)
Cooling / Heating
A
3,20 / 3,80
4,8 / 4,90
Maximum current
A
5,3
6,7
Air volume
Cooling / Heating
m³/h
702 / 768
738 / 768
Moisture removal volume
l/h
1,5
2
Sound pressure level 
2)
Cooling (Hi / Lo / Q-Lo) dB(A)
41 / 26 / 22
42 / 30 / 22
Heating (Hi / Lo / Q-Lo) dB(A)
41 / 27 / 25
42 / 33 / 25
Sound power level
Cooling (Hi)
dB
57
58
Heating (Hi)
dB
57
58
Dimensions
H x W x D
mm
290 x 870 x 214
290 x 870 x 214
Net weight
kg
9
9
Air purifier filter
No
No
Outdoor Unit
Air volume
Cooling / Heating
m³/h
1.926 / 1.872
1.860 / 1.860
Sound pressure level 
2)
Cooling (Hi)
dB(A)
47
48
Heating (Hi)
dB(A)
48
50
Sound power level
Cooling (Hi)
dB
62
63
Heating (Hi)
dB
63
65
Dimensions 
3)
H x W x D
mm
542 x 780 x 289
542 x 780 x 289
Net weight
kg
31
33
Piping connections
Liquid pipe
inch (mm)
1/4 (6,35)
1/4 (6,35)
Gas pipe
inch (mm)
3/8 (9,52)
3/8 (9,52)
Refrigerant loading
R410A
kg
0,85
1,00
Elevation difference (in/out) 
4)
Max
m
15
15
Piping length
Min / Max
m
3 / 15
3 / 15
Precharge length
Max
m
7,5
7,5
Additional gas
g/m
20
20
Operating range
Cooling Min / Max
°C
5 / +43
5 / +43
Heating Min / Max
°C
-10 / +24
-10 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with QKE units.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. Q-Lo: The lowest fan speed. Lo: The second lowest fan speed. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.