Panasonic CS-E12QKEW User Manual

Page of 92
6,50 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
Prevention
allergen filter
ANTI BACTERIAL 
FILTER
MRE Multi Inverter models are powerful and efficient and are always there when you need them.
Furthermore, with the Anti Bacterial Filter, you can always enjoy the best quality air, without viruses, moulds or 
bacteria.
MRE WALL MOUNTED 2x1
STANDARD INVERTER
E
nergy 
saving
4,00 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
Kit
KIT-2MRE77-PBE
KIT-2MRE79-PBE
KIT-2MRE712-PBE
KIT-2MRE99-PBE
KIT-2MRE77-PKE
KIT-2MRE79-PKE
Indoor
CS-MRE7PKE
CS-MRE7PKE
CS-MRE7PKE
CS-MRE9PKE
CS-MRE7PKE
CS-MRE7PKE
CS-MRE7PKE
CS-MRE9PKE
CS-MRE12PKE
CS-MRE9PKE
CS-MRE7PKE
CS-MRE9PKE
Outdoor
CU-2RE15PBE
CU-2RE15PBE
CU-2RE15PBE
CU-2RE15PBE
CU-2RE18PBE
CU-2RE18PBE
Cooling capacity
Nominal (Min - Max)
kW
4,00 (1,50 - 4,60)
4,40 (1,50 - 4,80)
4,40 (1,50 - 4,80)
4,40 (1,50 - 4,80)
4,00 (1,50 - 4,60)
4,50 (1,50 - 4,80)
Nominal (Min - Max)
kCal/h
3.440 (1.290 - 3.956)
3.784 (1.290 - 4.128)
3.784 (1.290 - 4.128)
3.784 (1.290 - 4.128)
3.440 (1.290 - 3.956)
3.870 (1.290 - 4.128)
Cooling capacity room A
Nominal
kW
2,00
1,95
1,70
2,20
2,00
2,00
Cooling capacity room B
Nominal
kW
2,00
2,45
2,70
2,20
2,00
2,50
SEER
Nominal
Energy Saving 6,30 i
6,50 i
6,50 i
6,50 i
6,10 i
6,30 i
Pdesign (cooling)
kW
4,40
4,40
4,40
4,40
4,80
4,80
Power input cooling
Nominal (Min - Max)
kW
1,170 (0,270 - 1,340)
1,300 (0,270 - 1,520)
1,300 (0,270 - 1,520)
1,300 (0,270 - 1,520)
1,160 (0,270 - 1,340)
1,400 (0,270 - 1,510)
Annual electricity consumption (cooling) 
1)
kWh/a
237
237
237
237
Heating capacity
Nominal (Min - Max)
kW
4,80 (1,10 - 6,30)
4,80 (1,10 - 6,30)
4,80 (1,10 - 6,50)
4,80 (1,10 - 6,50)
5,20 (1,10 - 6,30)
5,20 (1,10 - 6,30)
Nominal (Min - Max)
kCal/h
4.128 (946 - 5.418)
4.128 (946 - 5.418)
4.128 (946 - 5.590)
4.128 (946 - 5.590)
4.472 (946 - 5.418)
4.472 (946 - 5.418)
Heating capacity at -7°C
Nominal
kW
3.220
3.220
3.220
3.220
3.540
3.540
Heating capacity room A
Nominal
kW
2,40
2,15
1,85
2,40
2,60
2,60
Heating capacity room B
Nominal
kW
2,40
2,65
2,95
2,40
2,60
2,90
SCOP
Nominal
Energy Saving 3,80 a
4,00 h
4,00 h
4,00 h
3,80 a
3,80 a
Pdesign at -10°C
kW
3,60
3,60
3,60
3,60
3,80
3,80
Power input heating
Nominal (Min - Max)
kW
1,200 (0,240 - 1,610)
1,200 (0,240 - 1,610)
1,200 (0,240 - 1,670)
1,200 (0,240 - 1,670)
1,300 (0,240 - 1,610)
1,300 (0,240 - 1,610)
Annual electricity consumption (heating) 
1)
kWh/a
1.260
1.260
1.260
1.260
Indoor unit
Connection
mm²
4 x 1,5
4 x 1,5
4 x 1,5
4 x 1,5
4 x 1,5
4 x 1,5
Current (Nominal)
Cooling / Heating
A
5,45 / 5,35
6,10 / 5,35
6,10 / 5,35
6,10 / 5,35
5,45 / 5,80
6,10 / 5,80
Air volume
Cooling
m³/h
606 (E7) / 606 (E7)
606 (E7) / 618 (E9)
606 (E7) / 654 (E12)
618 (E9) / 618 (E9)
606 (E7) / 606 (E7)
606 (E7) / 618 (E9)
Moisture removal volume
Cooling
l/h
1,3 (E7) / 1,3 (E7)
1,3 (E7) / 1,5 (E9)
1,1 (E7) / 1,6 (E12)
1,4 (E9) / 1,4 (E9)
1,3 (E7)
1,3 (E7) / 1,5 (E9)
Sound pressure level 
2)
Cooling & Heating (Lo)
dB(A)
29 (E7) / 29 (E7) 
29 (E7) / 29 (E9) 
29 (E7) / 32 (E12) 
29 (E9) / 29 (E9) 
29 (E7) / 29 (E7) 
29 (E7) / 29 (E9) 
Sound power level
Cooling & Heating (Hi)
dB
56 (E7) / 56 (E7) 
56 (E7) / 56 (E9) 
56 (E7) / 60 (E12) 
56 (E9) / 56 (E9) 
56 (E7) / 56 (E7) 
56 (E7) / 56 (E9) 
Dimensions
H x W x D
mm
290 x 870 x 214
290 x 870 x 214
290 x 870 x 214
290 x 870 x 214
290 x 870 x 214
290 x 870 x 214
Net weight
kg
9
9
9
9
9
9
Air purifier filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Outdoor unit
Power source
V
230
230
230
230
230
230
Recommended fuse
A
16
16
16
16
16
16
Recommended power cable section
mm²
1,5
1,5
1,5
1,5
1,5
1,5
Air volume
Cooling / Heating
m³/h
1.962 / 1.962
1.962 / 1.962
1.962 / 1.962
1.962 / 1.962
2.214 / 2.416
2.214 / 2.416
Sound pressure level 
2)
Cooling / Heating (Hi)
dB(A)
47 / 49
47 / 49
47 / 49
47 / 49
49 / 51
49 / 51
Sound power level
Cooling / Heating (Hi)
dB
62 / 64
62 / 64
62 / 64
62 / 64
64 / 66
64 / 66
Dimensions 
3)
H x W x D
mm
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
Net weight
kg
39
39
39
39
39
39
Piping connections
Liquid pipe / Gas pipe
inch (mm)
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
Refrigerent Loading
R410A
kg
39
1,45
1,45
1,45
1,45
1,45
Elevation difference (in/out) 
4)
Max
m
10
10
10
10
10
10
Piping length (total)
Min / Max
m
3 / 30
3 / 30
3 / 30
3 / 30
3 / 30
3 / 30
Piping length (one unit)
Min / Max
m
3 / 20
3 / 20
3 / 20
3 / 20
3 / 20
3 / 20
Precharge length
Max
m
20
20
20
20
20
20
Additional charge
g/m
20
20
20
20
20
20
Operating range
Cooling Min / Max
°C
16 / 43
16 / 43
16 / 43
16 / 43
16 / 43
16 / 43
Heating Min / Max
°C
-10 / 24
-10 / 24
-10 / 24
-10 / 24
-10 / 24
-10 / 24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
Down to
-10 ºC
 in
heating mode
OUTDOOR
TEMPERATURE
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
60