Panasonic CS-E12QKEW User Manual

Page of 92
Silver Kit
KIT-2XE77-QBE
KIT-2XE79-QBE
KIT-2XE712-QBE
KIT-2XE99-QBE
Silver Kit with Smartphone Control
KIT-2XE77-QBE-WIFI
KIT-2XE79-QBE-WIFI
KIT-2XE712-QBE-WIFI
KIT-2XE99-QBE-WIFI
Indoor
CS-XE7QKEW (x2)
CS-XE7QKEW + CS-XE9QKEW
CS-XE7QKEW + CS-XE12QKEW
CS-XE9QKEW (x2)
White Kit
KIT-2E77-QBE
KIT-2E79-QBE
KIT-2E712-QBE
KIT-2E99-QBE
White Kit with Smartphone Control
KIT-2E77-QBE-WIFI
KIT-2E79-QBE-WIFI
KIT-2E712-QBE-WIFI
KIT-2E99-QBE-WIFI
Indoor
CS-E7QKEW (x2)
CS-E7QKEW + CS-E9QKEW
CS-E7QKEW + CS-E12QKEW
CS-E9QKEW (x2)
Outdoor
CU-2E15PBE
CU-2E15PBE
CU-2E15PBE
CU-2E15PBE
Cooling capacity
Nominal (Min - Max)
kW
4,00 (1,50 - 5,00)
4,50 (1,50 - 5,20)
4,50 (1,50 - 5,20)
4,50 (1,50 - 5,20)
Nominal (Min - Max)
kCal/h
3.440 (1.290 - 4.300)
3.870 (1.290 - 4.470)
3.870 (1.290 - 4.470)
3.870 (1.290 - 4.470)
SEER
Nominal
Energy Saving
6,50 i
Pdesign (cooling)
kW
4,50
Power input cooling
Nominal (Min - Max)
kW
1,090 (0,250 - 1,350)
1,230 (0,250 - 1,520)
1,230 (0,250 - 1,530)
1,230 (0,250 - 1,520)
Annual electricity consumption (cooling) 
1)
kWh/a
242
Heating capacity
Nominal (Min - Max)
kW
5,40 (1,10 - 7,00)
5,40 (1,10 - 7,00)
5,40 (1,10 - 7,00)
5,40 (1,10 - 7,00)
Nominal (Min - Max)
kCal/h
4.644 (946 - 6.020)
4.644 (946 - 6.020)
4.644 (946 - 6.020)
4.644 (946 - 6.020)
Heating capacity at -7°C
Nominal
kW
5.980
5.980
5.980
5.980
Heating capacity at -15°C
Nominal
kW
3.993
3.993
3.993
3.993
SCOP
Nominal
Energy Saving
4,00 h
Pdesign at -10°C
kW
4,00
Power input heating
Nominal (Min - Max)
kW
1,170 (0,210 - 1,670)
1,170 (0,210 - 1,670)
1,170 (0,210 - 1,670)
1,170 (0,210 - 1,670)
Annual electricity consumption (heating) 
1)
kWh/a
1.400
Indoor Unit
Connection
mm²
4 x 1,5
4 x 1,5
4 x 1,5
4 x 1,5
Current (Nominal)
Cooling / Heating
A
5,10 / 5,20
5,75 / 5,20
5,75 / 5,20
5,75 / 5,20
Air volume
Cooling
m³/h
(E7) 684
684 (E7) / 702 (E9)
684 (E7) / 732 (E12)
(E9) 702
Moisture removal volume
l/h
1,3 / 1,3
1,3 (E7) / 1,8 (E12)
1,3 (E7) / 1,8 (E12)
1,5 / 1,5
Sound pressure level 
2)
Cooling (S-Lo)
dB(A)
(E7) 23
(E7) 23 / (E9) 23
(E7) 23 / (E12) 23
(E9) 23 / (E9) 23
Sound power level
Cooling (S-Lo)
dB
(E7) 56
(E7) 56 / (E9) 56
(E7) 56 / (E12) 60
(E9) 56 / (E9) 56
Dimensions
H x W x D
mm
295 x 870 x 255
295 x 870 x 255
295 x 870 x 255
295 x 870 x 255
Net weight
kg
10
10
10
10
Air purifier filter
Nanoe-G
Nanoe-G
Nanoe-G
Nanoe-G
Outdoor Unit
Power source
V
230
230
230
230
Recommended fuse
A
16
16
16
16
Recommended power cable section
mm²
1,5
1,5
1,5
1,5
Air volume
Cooling / Heating
m³/h
1.962 / 2.214
1.962 / 2.214
1.962 / 2.214
1.962 / 2.214
Sound pressure level 
2)
Cooling / Heating (Hi)
dB(A)
47 / 49
47 / 49
47 / 49
47 / 49
Sound power level
Cooling / Heating (Hi)
dB
62 / 64
62 / 64
62 / 64
62 / 64
Dimensions 
3)
H x W x D
mm
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
Net weight
kg
39
39
39
39
Piping connections
Liquid pipe / Gas pipe
inch (mm)
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
Refrigerant loading
R410A
kg
1,40
1,40
1,40
1,40
Elevation difference (in/out) 
4)
Max
m
10
10
10
10
Piping length (total)
Min / Max
m
3 / 30
3 / 30
3 / 30
3 / 30
Piping length (one unit)
Min / Max
m
3 / 20
3 / 20
3 / 20
3 / 20
Precharge length
Max
m
20
20
20
20
Additional charge
g/m
15
15
15
15
Operating range
Cooling Min / Max
°C
-10 / 46
-10 / 46
-10 / 46
-10 / 46
Heating Min / Max
°C
-15 / 24
-15 / 24
-15 / 24
-15 / 24
Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding 
efficiency, comfort and healthy air combined with state-of-the-art design
Econavi features an in-built human activity sensor and a new sunlight detection technology to adjust output 
thereby giving you the best comfort at anytime whilst saving energy. Econavi not only optimizes air flow 
orientation and volume according to human presence, it also reduces cooling power automatically by no/less 
sunshine. With Econavi, energy savings of up to 38% are possible, whilst increasing your comfort.
Furthermore, the Nanoe-G revolutionary air-purifying system utilises nano technology fine particles to remove 
and deactivate 99% of both airborne and adhesive micro-organisms like bacteria, viruses and mould.
Using a Multi Split 2x1 Inverter+ system with the outdoor unit CU-2E15PBE instead of 2 individual mono split 
Inverter+ systems, you reduce consumption and thus save more! Up to 16%! Furthermore, using a Multi Split 
system, you save space on the outdoor unit, making it easier to install in small spaces.
ETHEREA MULTI SPLIT 2x1
INVERTER+
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-2XE79-QBE and KIT-2E79-QBE.
4,00 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
E
nergy 
saving
Easy
control
by BMS
CONNECTIVITY
Up to 
38%
energy savings
(cooling)
Air purifier 
99%
 
removal
bacteria · virus · mold
Down to
-15 ºC
 in
heating mode
OUTDOOR
TEMPERATURE
Improved
comfort
AUTOCOMFORT
6,50 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: CS-E/XE_QKE units are only compatible with CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E27PBE and CU-4E27PBE outdoor units. No other outdoor unit can be connected.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
Awarded the prestigious
IF Design Award 2013
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
62