Energizer ENCR1632 633676 Data Sheet

Product codes
633676
Page of 1
Classification:
"Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Nominal Voltage:
3.0 Volts
Typical Capacity:
130 mAh (to 2.0 volts)
(Rated at 15K ohms at 21°C)
Typical Weight:
1.8 grams (0.06 oz.)
Typical Volume:
0.5 cubic centimeters (0.03 cubic inch)
Max Rev Charge:
1 microampere
Energy Density:
209 milliwatt hr/g, 754 milliwatt hr/cc
Typical Li Content:
0.036 grams (0.0013 oz.)
UL Listed:
MH12454
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Load
Cutoff
2.0V
(ohms)
(hours)
15,000
684
Bkgnd Drain: Continuous
15K ohms
0.19 mA @2.9V
Pulse Drain: 2 seconds X 12 times/day
400 ohms
6.8 mA @2.7V
(2) Battery compartment design. To prevent children from removing 
batteries, battery compartments should be designed with one of the 
following methods: a) a tool such as screwdriver or coin is required to 
open battery compartment or b) the battery compartment door/cover 
requires the application of a minimum of two independent and 
simultaneous movements of the securing mechanism to open by hand. 
Screws should remain captive with the battery door or cover.
Lithium Coin
Global (except US):
ENERGIZER CR1632
Schedule:
Specifications
mm (inches)
Industry Standard Dimensions
United States:
Simulated Application test
Typical Performance at 21°C (70°F)
Typical Drains:
Safety:
(1) KEEP OUT OF REACH OF CHILDREN.  Swallowing may lead to 
serious injury or death in as little as 2 hours due to chemical burns and 
potential perforation of the esophagus.  Immediately see doctor; have 
doctor phone (202) 625-3333. 
Continuous
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
at 2.9V 
(mA)
0.19
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication. 
PRODUCT DATASHEET
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
200
400
600
800
V
o
lt
a
g
e
, CCV
Service, Hours
Load: 15K ohms - Continuous
Typical Drain @ 2.9V: 0.19 mA
15
30
45
60
75
90
105
120
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
30
60
90
120
150
IR,
 o
h
m
s
V
o
lt
a
g
e
, CCV
Capacity, mAh
IR
Pulse
Bkgnd
1-800-383-7323 USA/CAN
www.energizer.com
3.20 (0.126)
3.00 (0.118)
16.00 (0.630)
15.75 (0.620)
This Battery has Underwriters 
Laboratories component Recognition
Form No. EBC - 4126G
Page 1 of 1