Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
1-27 
 
 
•  CONNECTION EXAMPLE 
 
i. Jumper wire JP2 is not disconnected
 
 for Dry Contact Type a 
 
 
ii. Jumper Wire JP2 is disconnected
 
 for Dry Contact Type b 
 
 
 
Please refer to the actual manual supplied with the optional connecting cord SPX-WDC3 for more details. 
Window 
Close: ON 
Open: OFF 
Window 
Close: ON 
Open: OFF 
Card key unit 
Insert Card: ON 
Remove Card: OFF 
Indoor unit 
PWB 
Connection 
Connection 
SERIAL CONNECTION 
All SW ON → OPERATION 
Connecting cord to PCB 
Accessory# SPX-WDC3 
Window 
Close: OFF 
Open: ON 
Window 
Close: OFF 
Open: ON 
Card key unit 
Insert Card: OFF 
Remove Card: ON 
Indoor unit 
PWB 
Connection 
Connection 
PARALLEL CONNECTION 
All SW OFF → OPERATION 
Connecting cord to PCB 
Accessory# SPX-WDC3