Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
GENERAL DATA 
2-2
 
 
2.1.   MONOZONE / MULTIZONE 
2.1.1.  WALL TYPE (RAK-18QXA/25QXA/35QXA/50QXA) 
INDOOR 
Unit 
RAK-18QXA 
RAK-25QXA 
RAK-35QXA 
RAK-50QXA 
Nominal capacity adjustable  
  
1,20 ← 1,80 
Nominal Cooling capacity (min - max) 
kW 
1.8 (1.0-2.5) 
2.5 (1.0-3.1) 
3.5 (1.0-4.0) 
5.0 (0.9-5.2) 
Cooling sensible capacity  
kW 
0.0 
0.0 
0.0 
0.0 
Nominal Heating capacity (min - max) 
kW 
2.5 (1.0-3.1) 
3.4 (1.1-4.4) 
4.2 (1.1-5.0) 
6.5 (0.9-8.1) 
Noise level cooling (sound pressure) 
(SL / L / M / H) 
dB(A) 
20/23/26/32 
20/26/32/37 
22/29/35/39 
25/31/39/47 
Noise level heating (sound pressure) 
(SL / L / M / H) 
dB(A) 
20/24/27/33 
20/27/33/39 
22/30/35/41 
25/31/39/48 
Noise level (sound power) 
dB(A) 
54 
57 
59 
59 
Air flow cooling mode (SL / L / M / H) 
m
3
/h 
180/228/252/396  240/360/420/510  276/336/420/522  288/408/552/690 
Air flow heating mode (SL / L / M / H)  
m
3
/h 
180/228/252/450  198/318/420/570  264/396/510/618  288/432/570/780 
Fan Motor 
25 
25 
25 
25 
Drain pump pressure lift 
cm 
Static pressure (SL / L / M / H)  
Pa 
Dehumidification 
l/h 
1.2 
1.4 
1.6 
2.8 
Included drain pump 
 
-
 
-
 
-
 
-
 
Max. height available for drain pump 
(RAD/RAI only) 
 
-
 
-
 
-
 
-
 
Dimensions (H x W x D) 
mm 
295x795x198 
295x795x198 
295x795x198 
295x795x198 
Panel dimensions (H x W x D) 
mm 
Weight 
kg 
9.5 
9.5 
9.5 
9.5 
Colour (Munsell Code) 
 
White(*ZYYD6) 
Condensate Drain 
mm 
φ16 
φ16 
φ16 
φ16 
Panel weight 
kg 
Panel reference 
 
Color of the panel (RAL) 
 
Running current 
REFER TO OUTDOOR 
Power supply 
 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
Cable section 
mm² 
N/A 
N/A 
N/A 
N/A 
Piping diameter (Liq / Gas) 
  
1/4" / 3/8" 
1/4" / 3/8" 
1/4" / 3/8" 
1/4" / 1/2" 
Drain diameter (ext) 
mm 
φ16 
φ16 
φ16 
φ16 
Remote control (standard/optional)  * 
 
RAR-5E2/ 
SPX-RCDB 
RAR-5E2/  
SPX-RCDB
 
RAR-5E2/  
SPX-RCDB
 
RAR-5E2/  
SPX-RCDB
 
Filter 
 
 
 
 
 
ACL Filter 
 
Wasabi 
Wasabi 
Wasabi 
Wasabi 
Dimensions (H x W x D) 
mm 
48x243x5 
48x243x5 
48x243x5 
48x243x5 
Pre-filter (Standard / Optional) 
 
Nano Stainless/- 
Nano Stainless/-
 
Nano Stainless/-
 
Nano Stainless/-
 
*
more information regarding remote control can be found in Chapter 9.
 
 
NOTE: 
1.  The nominal cooling and heating capacity is the 
combined capacity of the HITACHI standard split 
system, and are based on the ISO 5151.
 
 
2.  The Sound Pressure Level is based on the following 
conditions:  
0.8 meter beneath indoor height center 
1 meter from Discharge grille 
The above data was measured in an anechoic 
chamber. Please take into consideration reflected 
sound of your specific site 
 
Operation Conditions 
Cooling 
Heating 
 
Indoor Air Inlet Temperature
 
dB 
27.0 °C
 
20.0 °C 
 
WB 
19.0 °C
 
 
 
Outdoor Air Inlet Temperature
 
dB 
35.0 °C
 
7.0 °C
 
 
WB 
 
6.0 °C 
 
Piping Length: 5.0 meters; Piping Lift: 0 meter 
dB: Dry Bulb; WB: Wet Bulb