CAPACITIES AND SELECTION DATA
4-283
4.3.20. RAK-25PEA/RAC-25WEA
COOLING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EWB EDB
-10
21
27
32
35
40
43
°C °C TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
12.0 18
2008 1610 403 2047 1932 431 1894 1783 508 2050 1941 644 1975 1856 672 1850 1749 721 1775 1664 749
14.0 20
2008 1610 403 2199 1932 431 2047 1802 514 2200 1941 651 2125 1877 679 1975 1749 728 1900 1685 763
16.0 22
2008 1713 410 2352 1932 437 2177 1802 520 2350 1941 658 2275 1877 693 2125 1749 742 2050 1685 770
18.0 25
2153 1837 416 2504 2099 442 2308 1951 526 2500 2112 665 2400 2026 693 2250 1898 749 2150 1813 777
19.0 27
2226 1899 422 2591 2211 448 2395 2044 532 2600 2218 672 2500 2133 700 2350 2005 749 2250 1920 777
22.0 30
2468 1878 422 2874 2192 448 2656 2025 532 2875 2197 679 2775 2112 707 2500 2048 777 2325 2005 819
24.0 32
2637 1878 428 3070 2192 454 2831 2025 538 3075 2197 679 2950 2112 714 2600 2090 798 2375 2069 847
HEATING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EDB
-15
-10
-7
-5
0
7
10
15
°C
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
16
1224
0 651 1938
0 669 2209
0 697 2390
0 716 2910
0 802 3437
0 812 3750
0 834 4328
0 876
18
1207
0 660 1921
0 678 2188
0 712 2366
0 735 2880
0 822 3420
0 854 3737
0 871 4311
0 917
20
1190
0 669 1904
0 686 2169
0 723 2346
0 748 2856
0 836 3400
0 880 3655
0 911 4284
0 959
22
1173
0 678 1887
0 695 2142
0 738 2312
0 767 2825
0 856 3380
0 915 3696
0 944 4264
0 999
24
1156
0 686 1870
0 704 2123
0 753 2292
0 786 2802
0 876 3359
0 950 3675
0 980 4202
0 1039
4.3.21. RAK-35PEA/RAC-35WEA
COOLING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EWB EDB
-10
21
27
32
35
40
43
°C °C TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
12.0 18
2179 1854 487 2056 2060 482 1903 1901 567 2870 2884 1003 2765 2757 1046 2590 2599 1123 2485 2472 1166
14.0 20
2179 1854 487 2209 2060 482 2056 1921 574 3080 2884 1014 2975 2789 1057 2765 2599 1134 2660 2504 1188
16.0 22
2179 1973 494 2363 2060 488 2188 1921 581 3290 2884 1025 3185 2789 1079 2975 2599 1155 2870 2504 1199
18.0 25
2336 2115 502 2516 2238 494 2319 2080 588 3500 3137 1036 3360 3011 1079 3150 2820 1166 3010 2694 1210
19.0 27
2415 2187 509 2603 2357 501 2406 2179 594 3640 3296 1046 3500 3169 1090 3290 2979 1166 3150 2852 1210
22.0 30
2678 2163 509 2888 2337 501 2669 2159 594 4025 3264 1057 3885 3137 1101 3500 3042 1210 3255 2979 1275
24.0 32
2861 2163 517 3084 2337 507 2844 2159 601 4305 3264 1057 4130 3137 1112 3640 3106 1243 3325 3074 1319
HEATING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EDB
-15
-10
-7
-5
0
7
10
15
°C
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
16
1512
0 814 2394
0 836 2729
0 872 2953
0 895 3595
0 1002 4246
0 1015 4633
0 1043 5347
0 1095
18
1491
0 825 2373
0 847 2703
0 890 2923
0 919 3557
0 1027 4225
0 1067 4616
0 1089 5326
0 1146
20
1470
0 836 2352
0 858 2680
0 904 2898
0 935 3528
0 1045 4200
0 1100 4515
0 1139 5292
0 1199
22
1449
0 847 2331
0 869 2646
0 923 2856
0 959 3490
0 1070 4175
0 1144 4565
0 1180 5267
0 1249
24
1428
0 858 2310
0 880 2622
0 941 2831
0 982 3461
0 1096 4150
0 1188 4540
0 1225 5191
0 1299
EWB : Evaporator Wet Bulb temperature (
C)
TC : Total Capacity (W)
EDB : Evaporator Dry Bulb temperature (
C)
SHC : Sensible Heating Capacity (W)
(
CDB) : Outdoor Unit Inlet Air Dry Temperature (
C)
PI : Power Input