Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
GENERAL DATA 
2-10
 
 
OUTDOOR 
UNIT 
RAM-70NP4A 
RAM-90NP5A 
RAM-130NP6A 
Minimum / Maximum indoor units 
connectable 
 
2 / 4 
2 / 5 
2/3 (units per ref. cycle) 
Minimum / Maximum connected capacity 
  
7.0kW 
8.5Kw 
12.6kW 
Nominal Cooling capacity (min - max) 
kW 
7.0 (2.4-8.8) 
8.5 (1.5-9.5) 
12.6 (1.5-13.2) 
Nominal Heating capacity (min - max) 
kW 
8.5 (2.8-9.5) 
11.0 (1.5-11.5) 
14.4 (1.5-14.4) 
Nominal cooling power input (min - max) 
kW 
2.11 (0.46-3.20) 
2.23 (0.20-3.85) 
4.19 (0.2-4.4) 
Nominal heating power input (min - max) 
kW 
2.11 (0.48-3.12) 
2.46 (0.20-3.85) 
3.8 (0.2-4.22) 
EER / COP 
 
3.32/4.03 
3.81/4.47 
3.01/3.79 
SEER / SCOP 
 
5.7/3.8 
5.3/4.8 
Energy class (SEER/SCOP) 
 
A+/A 
A/A++ 
A/A 
Noise level cooling (sound pressure) 
dB(A) 
53 
55 
55 
Noise level heating (sound pressure) 
dB(A) 
56 
58 
56 
Noise level (sound power) 
dB(A) 
68 
68 
68 
Air flow (Cooling / Heating) 
m
3
/h 
2700 / 2700 
3900 / 3900 
4320 / 4320 
Static pressure (nominal conditions, 
maximum) 
Pa 
Dimensions (H x W x D) 
mm 
800x850x298 
800x950x370 
1450x855x308 
Weight 
kg 
55.0 
71.0 
113.0 
Colour (Munsell Code) 
 
Beige (5Y 7/2)
 
Beige (5Y 7/2)
 
Beige (5Y 7/2)
 
Power supply 
 
220-240V/1ph/  50/60Hz  220-240V/1ph/  50/60Hz  220-240V/1ph/  50/60Hz 
Recommended fuse size 
30 
30 
30 
Starting current 
9.7 
16.0 
20.0 
Running current 
9.70-8.90/9.70-8.90 
10.20-9.40/11.30-10.40  19.20-17.60/17.40-16.00 
Cable section 
mm
2
 
Interconnection between indoor unit and 
outdoor unit 
mm
2
 
1.6 or 2.0 
1.6 or 2.0 
1.6 or 2.0 
Piping diameter (Liq / Gas) 
  
( 1/4" x 4 ) /  
(3/8" x 3 + 1/2" x 1) 
1/4" x 5 /  
(3/8" x 3) + (1/2" x 2) 
(1/4" x 6 / 3/8") x 6 
Minimum piping length 
5.0 
5.0 
5.0 
Maximum piping length / height 
difference 
60 / 20 
75 / 20 
45/45 / 20/20 
Current quantity of refrigerant / 
Chargeless 
kg 
2.30 
2.70 
1.65 
Chargeless / Additional refrigerant 
charge 
m / g/m 
30/20 
30/15 
35/20 
Working range (cooling / heating) 
°C 
-10 ~ 43 / -15 ~ 21 
-10 ~ 43 / -15 ~ 21 
-10 ~ 43 / -15 ~ 21 
Refrigerant 
 
R410A 
R410A 
R410A 
Condenser Fan 
 
Propeller Fan 
Compressor 
Type 
 
2 Cylinder Rotary 
2 Cylinder Rotary 
2 Cylinder Rotary 
Oil Type 
 
HAF68D1/ 
68HES-H
 
HAF68D1/ 
68HES-H
 
HAF68D1/ 
68HES-H
 
Oil Charge 
ml 
840 
1000 
960 
Coil Resistance 
 
1.05 at 20
0.41 at 20
1.063 at 25
1.268 at 75
0.50 at 75
1.268 at 75
Quantity 
 
 
NOTE: 
1.  The nominal cooling and heating capacity is the combined capacity of the 
HITACHI standard split system, and are based on the ISO 5151. 
 
2. The Sound Pressure Level is based on the 
following conditions:  
1.5 meter beneath the Unit  
The above data was measured in an 
anechoic chamber. Please take into 
consideration reflected sound of your 
specific site 
 
 
Operation Conditions 
Cooling 
Heating 
 
Indoor Air Inlet Temperature
 
dB 
27.0 °C
 
20.0 °C 
 
WB 
19.0 °C
 
 
 
Outdoor Air Inlet Temperature
 
dB 
35.0 °C
 
7.0 °C
 
 
WB 
 
6.0 °C 
 
Piping Length: 5.0 meters; Piping Lift: 0 meter 
dB: Dry Bulb; WB: Wet Bulb