WORKING RANGE 
5-2
 
 
 
5.1.  POWER SUPPLY 
Working Voltage 
198V ~ 264V 
Voltage Imbalance 
Within a 3% Deviation from Each Voltage at the Main Terminal of 
Outdoor Unit 
Starting Voltage 
Higher than 85% of the Rated Voltage 
 
5.2.  WORKING RANGE 
5.2.1.  MONO SPLIT - PREMIUM 
Applicable models: 
PREMIUM 
RAC-18WSA 
RAC-18WSAN 
RAC-25WSA 
RAC-25WSAN 
RAC-35WSA 
RAC-35WSAN 
 
The temperature range is indicated in the following table. 
 
Cooling 
 
 
 
 
Heating 
 
 
 
working range 
min (
o
C) 
max (
o
C) 
rated (
o
C) 
 
working range 
min (
o
C) 
max (
o
C) 
rated (
o
C) 
outdoor 
22 
43 
35 
 
outdoor 
-20 
21 
indoor 
16 
32 
27 
 
indoor 
16 
32 
20 
Cooling
0
10
20
30
40
50
0
10
20
30
40
Indoor temperature
Ambient temperature
 
 
Heating
-20
- 10
0
10
20
30
40
50
-10
0
10
20
30
40
Indoor temperature
Ambient temperature
 
 
Indoor Temperature 
Indoor Temperature 
Am
b
ie
n
T
e
m
p
e
ra
tu
re
 
Am
b
ie
n
T
e
m
p
e
ra
tu
re
 
Indoor Temperature 
COOLING 