Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 ELECTRICAL 
DATA
 
 
6-5 
 
 
 
 
 
 
 
 
 
 
 
 
Model 
Unit Main Power 
Compressor Motor 
VOL, PH, Hz 
Fuse Rating (A)  Min (V) Max (V)  Locked Rotor Ampere (A) 
STC 
Cooling 
Operation 
Heating Operation 
RNC 
IPT 
RNC 
IPT 
RAC-18WEA 
220~230, 1, 50 
15 
198 
253 
N/A 
2.78 
2.91 
494.4 
3.00 
564 
RAC-25WEA 
220~230, 1, 50 
15 
198 
253 
N/A 
3.16 
3.58 
690 
4.25 
907.9 
RAC-35WEA 
220~230, 1, 50 
15 
198 
253 
N/A 
4.81 
5.00 
1101.9 
5.03 
1122.7 
RAC-50WEA 
220~230, 1, 50 
15 
198 
253 
N/A 
7.24 
6.85 
1617 
7.29 
1709.5 
RAC-25FXA 
220~230, 1, 50 
16 
198 
253 
N/A 
3.99 
2.66 
580 
3.63 
790 
RAC-35FXA 
220~230, 1, 50 
16 
198 
253 
N/A 
5.84 
4.68 
1020 
5.860 
1220 
RAC-50FXA 
220 ~ 230, 1, 50 
16 
198 
253 
N/A 
8.2 
7.16 
1560 
8.17 
1780 
RAC-25FPA 
220~230, 1,50 
16 
198 
253 
N/A 
2.93 
3.34 
630.3 
4.11 
839.7 
RAC-35FPA 
220~230, 1,50 
16 
198 
253 
N/A 
3.81 
4.30 
869 
4.81 
1063.2 
RAC-50FPA 
220~230, 1,50 
16 
198 
253 
N/A 
4.46 
6.63 
1436.8 
7.29 
1652.9 
RAC-50DPA 
220 ~ 240, 1, 50 
30 
198 
264 
N/A 
10 
6.4 
1400 
7.3 
1590 
RAC-60DPA 
220 ~ 240, 1, 50 
30 
198 
264 
N/A 
10 
8.55 
1870 
9.75 
2130 
RAC-70DPA 
220 ~ 240, 1, 50 
30 
198 
264 
N/A 
10 
11.6 
2530 
10.7 
2340 
VOL:  Rated Unit Power Supply Voltage  (V) 
RNC: 
Running Current (A) 
HZ: 
Frequency (Hz) 
PH: 
Phase (
STC:  Starting Current (A) 
IPT: 
Input (W) 
NOTE: 
1.  The above compressor data is based on 100% capacity combination of indoor units at the rated operating frequency  
2.  This data is based on the same conditions as the nominal heating and cooling capacities. 
3.  The compressor started by an inverter, resulting in extremely low starting current.