Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
GENERAL DATA 
 
2-19 
 
2.2.9.  WALL TYPE (RAK-18PPA/25PPA/35PPA) 
INDOOR 
Unit 
RAK-18PPA 
RAK-25PPA 
RAK-35PPA 
Nominal capacity adjustable 
  
Nominal Cooling capacity (min - max) 
kW 
2.00 (0.90 - 2.50) 
2.50 (0.90 - 3.10) 
3.50 (0.90- 4.00) 
Cooling sensible capacity 
kW 
1.9 
2.1 
3.2 
Nominal Heating capacity (min - max) 
kW 
2.50 (0.90 - 3.20) 
3.40 (0.90- 4.40) 
4.20 (0.90- 5.00) 
Noise level cooling (sound pressure) 
(SL / L / M / H) 
dB(A) 
21/27/33/37 
22/24/33/40 
25/26/36/43 
Noise level heating (sound pressure) 
(SL / L / M / H) 
dB(A) 
19/28/34/38 
20/21/34/41 
26/27/36/44 
Noise level (sound power) 
dB(A) 
51 
54 
57 
Air flow cooling mode (SL / L / M / H) 
m
3
/h 
312/350/400/440 
333/370/430/510 
333/400/485/600 
Air flow heating mode (SL / L / M / H) 
m
3
/h 
312/350/420/480 
333/400/500/570 
333/520/550/ 660 
Fan Motor 
25 
25 
25 
Drain pump pressure lift 
cm 
Static pressure (SL / L / M / H) 
(nominal conditions SP 00) 
Pa 
Dehumidification 
l/h 
1.2 
1.4 
1.6 
Included drain pump 
 
no 
no 
no 
Max. height available for drain pump 
(RAD/RAI only) 
 
no 
no 
no 
Dimensions (H x W x D) 
mm 
280x780x218 
280x780x218 
280x780x218 
Panel dimensions (H x W x D) 
mm 
Weight 
kg 
7.5 
7.5 
7.5 
Colour (Munsell Code) 
 
White (N9.25) 
White (N9.25)
 
White (N9.25)
 
Condensate Drain 
mm 
φ16 
φ16
 
φ16
 
Panel weight 
kg 
Panel reference 
 
Color of the panel (RAL) 
 
Running current 
2.65/2.84 
3.58/4.25 
5.00/5.03 
Power supply 
 
35 V DC from outdoor 
unit 
35 V DC from outdoor 
unit 
35 V DC from outdoor 
unit 
Cable section 
mm² 
0.75x2 
0.75x2 
0.75x2 
Piping diameter (Liq / Gas) 
  
1/4” - 3/8” 
1/4” - 3/8” 
1/4” - 3/8” 
Drain diameter (ext) 
mm 
φ16 
φ16 
φ16 
Remote control (standard/optional)  * 
 
RAR-5E2/SPX-RCDB 
RAR-5E2/ SPX-RCDB
 
RAR-5E2/ SPX-RCDB
 
Filter 
 
 
 
 
ACL Filter 
 
Wasabi 
Wasabi 
Wasabi 
Dimensions (H x W x D) 
mm 
48x243x5 
48x243x5 
48x243x5 
Pre-filter (Standard / Optional) 
 
Washable/Stainless 
Washable/Stainless 
Washable/Stainless 
 
NOTE: 
1.  The nominal cooling and heating capacity is the 
combined capacity of the HITACHI standard split 
system, and are based on the ISO 5151.
 
 
2.  The Sound Pressure Level is based on the following 
conditions:  
Half height of the unit 
1 meter from Discharge grille 
The above data was measured in an anechoic 
chamber. Please take into consideration reflected 
sound of your specific site
 
 
Operation Conditions 
Cooling 
Heating 
 
Indoor Air Inlet Temperature
 
dB 
27.0 °C
 
20.0 °C 
 
WB 
19.0 °C
 
 
 
Outdoor Air Inlet 
Temperature
 
dB 
35.0 °C
 
7.0 °C
 
 
WB 
 
6.0 °C 
 
Piping Length: 5.0 meters; Piping Lift: 0 meter 