Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
REMOTE CONTROLLERS OPERATION
 
 
9-7 
 
9.1.1.4 
SETTING THE PREVENTION OF MUTUAL INTERFERENCE
 
 
1.
 
Please ensure the other indoor unit is OFF. 
2.
 
Press 
 (PROGRAM NO.) button, 
(ON TIMER) button and 
 (RESET) button simultaneously. The 
remote controller will display Screen 1 and followed by Screen 2. The indoor unit beeps to indicate that it has just 
received the signal from remote controller. 
   
 
 
 
 
Screen 1   
 
 
 
   Screen 2 
 
NOTE: 
1.
 
 If indoor unit still not receive the correct signal from the correct remote controller, setting shall be made 
again. By setting again for the 2nd time, the signal address will change from B to A, then repeat again for 
the 3rd time. 
2.
 
As for 
RAK-18PPA, RAK-25PPA, RAK-35PPA, RAF-50RPA, 
please set the pin No. 6 of the DIP switch 
at the indoor unit to ON position when selecting channel B for ID communication.
 
(Please refer to 
Chapter 1.3.2 for more information)
 
9.1.1.5 
ERROR CODE INFORMATION
 
1.
 
In case failure occurs to the air conditioner, by pressing 
(INFO) button, an error code will be displayed. 
2.
 
Direct the remote controller towards the receiver of indoor unit (within 2 meters in from of indoor unit) and press 
 (INFO) button. 
3.
 
Wait for 2 seconds for signal transmission and the error code will be displayed. 
 
 
TIMER 
LAMP 
BLINKING 
LED301 
BLINKING 
CODE 
MEANING 
INDO
O
R
 
000 
00 
Normal 
1 time 
 
001 
00 
Refrigerant cycle fault 
2 times 
Outdoor unit is under forced operation 
3 times 
9 times 
003 
00 
Communication error between indoor and outdoor 
units 
6 times 
006 
00 
Abnormal water level: ceiling/small duct 
9 times 
009 
00 
Indoor thermistor 
10 times 
010 
00 
Abnormal rotating numbers 
11 times 
011 
00 
High voltage generator defective 
12 times 
012 
00 
Outdoor power defective 
13 times 
013 
00 
IC401 data reading error 
O
UTDO
O
R
 
2 times 
002 
01 
Peak current cut 
3 times 
003 
01 
Compressor abnormal low speed rotation 
4 times 
4 times 
004 
01 
Compressor switching failure 
5 times 
005 
01 
Overload lower limit cut 
6 times 
006 
01 
OH thermistor temperature rise 
4 times 
7 times 
007 
01 
Abnormal outdoor thermistor 
4 times 
8 times 
008 
01 
Acceleration defective