(The plug can be secured diagonally with a screw as 
shown above.) 
 
 WARNING 
• 
Be sure to attach screw 
 to prevent the indoor unit 
from overturn.
 
 
2.  Wall installation 
 
Direct mounting on the wall 
• 
Please remove 3 screws and clip which fix to the 
stand and cabinet. (As shown in the figure below) 
 
• 
Please remove the screws which fix the cabinet 
and hanger. 
• 
Please use hidden beams in the wall to hold the 
hanger. 
 
 
 
 
CAUTION 
• 
The draining of the water container inside the 
indoor unit can be done from the left. Therefore the 
hanger must be fixed horizontally or slightly tilted 
towards the side of drain hose. Otherwise, 
condensed water may overflor the water container. 
 
 
Procedure of installation and precautions. 
 
Procedure to fix the hanger and indoor unit. 
 
1.  Drill holes on wall (As 
shown below) 
2.  Push plug into the holes 
(As shown below) 
 
 
 
 
 
3.  Fix the hanger on wall with 4.1x32 and 4.0x34 screw. 
(As shown in figure below) 
 
 
4. Fix the indoor unit on the wall with 4.1x32 screw. 
 
 
 
3.  Built-in installation 
•  If outlet is covered with the lattice door, room 
temperature may not be controlled properly. Therefore, 
air outlet must be open as much as possible.
 
•  If air deflector of air outlet is adjusted too much 
upward, room temperature may not be controlled 
properly due to the heat inside the lattice door. 
Therefore, the deflector must be adjusted to nearly 
horizontal angle.
 
•  If signal receiver is covered with the lattice door, 
signal receiving distance or range (angle) becomes 
smaller. Therefore, single receiver must not be 
covered with the lattice door.
 
•  Only the vertical lattice door may be used. Besure to 
use a lattice door with an open area ratio of 75% or 
more. If another lattice door or one with an open area 
ratio of less than 75% is used, maximum performance 
may not be obtained.
 
•  With a built-in installation, it may take more time to 
reach the set temperature after the unit is switched on.
 
 
1. Drill holes on floor 
2. Push plug into the holes. 
Floor 
Indoor unit 
Screw  
(4.1x32) 
Plug 
(Procure 
locally) 
External dimension 
of indoor unit 
20mm 
Drain hose 
20mm 
750mm 
55mm 
50m
m
 
470
m
m
 
Hanger 
Level 
Hole for pipe 
Screw for Hanger  Weight 
Mark 
Line 
Please use more 
than 6 screws. 
Wall 
Wall 
Screw 
Hanger 
Plug 
 Screw (4.0x34) 
 Screw 
(4.0x34) 
 Screw (4.1x32) 
 Screw 
(4.1x32) 
 Screw 
(4.1x32)