Fixing the indoor
Fixing the top of indoor unit
WARNING
•
Even if there is space between the indoor unit and the
back wall, make sure to securely attach the indoor unit
to the wall, ceiling or floor using wire to prevent it from
falling.
back wall, make sure to securely attach the indoor unit
to the wall, ceiling or floor using wire to prevent it from
falling.
•
In the case of fixing by the anchor bolt, bury the Ø6
anchor bolt into the wall as shown in below. Lift up the
indoor unit slightly and hang.
anchor bolt into the wall as shown in below. Lift up the
indoor unit slightly and hang.
•
In the case of fixing by screw of accessory
•
Bury the plug into the wall as shown in below to attach
the screw ⑨. Lift up the indoor unit slightly and hang.
the screw ⑨. Lift up the indoor unit slightly and hang.
Fixing the base of indoor unit
•
Fix the base of indoor unit on the floor with 4.1 x
63mm screws. (Right and left)
63mm screws. (Right and left)
WARNING
•
Be sure to attach screw ③ to prevent the indoor unit
from overturn.
from overturn.
•
When fixing the indoor unit above the ground, be
sure to fix an L-angle at the bottom to support it
sure to fix an L-angle at the bottom to support it
•
To drill holes, either Case 1 or 2 may be used.
1. Drill holes on floor.
2. Push plug into the holes
BUILT-IN INSTALLATION
①If upper or lower air outlet is covered with lattice door,
room temperature may not be controlled properly.
Therefore, air outlet must be opened as much as
possible.
Therefore, air outlet must be opened as much as
possible.
②If air deflector or upper air outlet is adjusted too much
upward, room temperature may not be controlled properly
due to the heat inside the lattice door. Therefore, the
deflector must be adjusted to nearly horizontal angle.
due to the heat inside the lattice door. Therefore, the
deflector must be adjusted to nearly horizontal angle.
③If signal receiver is covered with the lattice door, signal
receiving distance or range (angle) becomes smaller.
Therefore, signal receiver must not be covered with the
lattice door.
Therefore, signal receiver must not be covered with the
lattice door.
④Only the vertical lattice door may be used. Be sure to use
a lattice door with an open area ratio of 75% or more. If
another lattice door or one with an open area ratio of less
than 75 is used, maximum performance may not be
obtained.
another lattice door or one with an open area ratio of less
than 75 is used, maximum performance may not be
obtained.
⑤With built-in installation it may take more time to reach the
set temperature after the unit is switched on.
(Procure locally)
Plug
φ4.
8m
m
Wall
32mm
Screw
Screw