Hitachi RAF-35RPA RAF35RPA User Manual
Product codes
RAF35RPA
GENERAL DATA
2-24
2.2.14. WALL TYPE (RAC-18WEA/25WEA/35WEA/50WEA)
OUTDOOR
UNIT
RAC-18WEA
RAC-25WEA
RAC-35WEA
RAC-50WEA
Minimum / Maximum indoor units
connectable
connectable
-
-
-
-
Minimum / Maximum connected
capacity
capacity
-
-
-
-
Nominal Cooling capacity (min - max)
kW
2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00)
5.00 (1.90- 5.20)
Nominal Heating capacity (min - max)
kW
2.50 (0.90 - 3.20) 3.40 (0.90- 4.40)
4.20 (0.90- 5.00)
6.00 (2.2- 7.30)
Nominal cooling power input (min -
max)
max)
kW
0.58 (0.25 - 1.01) 0.70 (0.25 - 1.29) 1.090 (0.25 - 1.46) 1.560 (0.50 - 2.10)
Nominal heating power input (min -
max)
max)
kW
0.62 (0.25 - 0.97) 0.88 (0.25 - 1.25) 1.100(0.25 - 1.70) 1.660(0.50 - 2.75)
EER / COP
3.45/4.03
3.57/3.86
3.21/3.82
3.21/3.61
SEER / SCOP
5.8/3.8
5.8/3.8
5.9/3.8
5.9/3.8
Energy class (SEER/SCOP)
A+/A
A+/A
A+/A
A+/A
Noise level cooling (sound pressure)
dB(A)
46
48
49
51
Noise level heating (sound pressure)
dB(A)
47
49
50
51
Noise level (sound power)
dB(A)
60
62
63
65
Air flow (Cooling / Heating)
m
3
/h
1860 / 1620
1860 / 1620
1920 / 1620
2160 / 2160
Static pressure (nominal conditions,
maximum)
maximum)
Pa
no
no
no
no
Dimensions (H x W x D)
mm
505x700x258
505x700x258
548×750×288
600x792x299
Weight
kg
27.0
27.0
36.0
40.0
Colour (Munsell Code)
Beige (5Y 7/2)
Power supply
230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz
Recommended fuse size
A
15
15
15
25
Starting current
A
2.97/3.00
3.58/4.25
5.00/5.03
6.85/7.29
Running current
A
2.97/3.00
3.58/4.25
5.00/5.03
6.85/7.29
Cable section
mm
2
3x1.50
3x1.50
3x1.50
3x2.50
Interconnection between indoor unit
and outdoor unit
and outdoor unit
mm
2
2x0.75
2x0.75
2x0.75
2x0.75
Piping diameter (Liq / Gas)
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
1/4” - 1/2”
Minimum piping length
m
5.0
5.0
5.0
5.0
Maximum piping length / height
difference
difference
m
20 / 10
20 / 10
20 / 10
20 / 10
Current quantity of refrigerant /
Chargeless
Chargeless
kg
0.82
0.82
1.00
1.25
Chargeless / Additional refrigerant
charge
charge
m / g/m
20/-
20/-
20/-
20/-
Working range (cooling / heating)
°C
-10~43/-15~21
-10~43/-15~21
-10~43/-15~21
-10~43/-15~21
Refrigerant
R410A
R410A
R410A
R410A
Condenser Fan
Propeller Fan
Compressor
Type
ROTARY
ROTARY
ROTARY
ROTARY
Oil Type
α68HES-H
α68HES-H
α68HES-H
HAF68DIU
Oil Charge
ml
320±20
320±20
320±20
440±20
Coil Resistance
0.74 at 25
C
0.74 at 25
C
0.74 at 25
C
0.74 at 25
C
2.4 at 75
C
2.4 at 75
C
2.4 at 75
C
2.4 at 75
C
Quantity
1
1
1
1
NOTE:
1. The Sound Pressure Level is based on the following conditions:
-
1 meter from the unit front surface and 1 meter from floor level
The above data was measured in an anechoic chamber. Please take into consideration reflected sound of your specific
site
site