10-23 
 
 
 CAUTION 
• 
A circuit breaker or fuse must be installed. Without a 
circuit breaker or fuse, the danger of electric shock 
exists. A main switch with a contact gap of more 
than 3.5mm has to be installed in the power supply 
line to the outdoor unit. 
• 
Do not install the unit near a location where there is 
a flammable gas. The indoor unit may catch fire if 
flammable gas leaks around it. 
• 
Be sure to tighten the flare nut to the specified 
torque using a  toque wrench. If the flare nut is 
tightened excessively, it may crack as time elapses, 
causing the refrigerant leakage. 
• 
Please ensure smooth flow of water when installing 
the drain hose. 
• 
Piping shall be suitable supported with a maximum 
spacing of 1m between supports 
• 
An IEC approved power cord should be used. Power 
cord type: NYM. 
• 
“Height difference “ and “Piping length” of Indoor and 
Outdoor unit differs depending on  the Outdoor unit. 
Please refer to the “Installation manual” in Outdoor 
unit 
 
 
Proper place for Installation 
Indoor unit 
Refrigerating pipes can be drawn from the back, the 
under the left side of the indoor unit. In the case that 
refrigerating pipes are drawn form the left side, confirm 
the smooth flowing of condensed water. If not, the 
condensed water will overflow into the room. When the 
pipes are drawn from the right or left side, the pipes can 
be connected easily by configuration the pipes before 
installation. 
Installation procedure and notice 
 
Especially, the selection of installation place need great 
care for the split type air conditioner, because it is very 
difficult to move from place to place after the first 
installation. 
1. 
Make a hole on the wall such that the place as 
shown in figure in order to keep the flow of 
condensed water smooth. 
 
 
2.  Hole on wall should be made with some inclination as 
above for keeping the smooth flow of condensed 
water. 
1.  Connecting pipe installation 
• 
Seal the end of pipes to prevent from moisture and 
water 
 
Unit :mm 
INSTALLATION OF FULL DUCT TYPE
 
 
Full duct type 
 
Need optional parts when install full duct type 
 
① 
Discharge grille 
② 
Chamber of discharge grille Ø150mm 
③ 
Chamber of discharge of unit side Ø150mm 
④ 
Chamber of suction of unit side Ø150mm 
⑤ 
Chamber of suction grille Ø150mm 
⑥ 
Suction grille 
⑦ 
Flexible duct Ø150mm 1m 
Flexible duct Ø150mm 2m 
 
 
Be sure to 
completely seal any 
gap with putty. 
Adiabated pipes 
must be used for 
both large and small 
daimeter. An 
adiabator will 
weather excessively 
if not eape-wrapped. 
Drain pipe must be installed 
separately. Insulate indoor 
part of pipe to prevent 
condensation. 
The indoor piping 
should be insulated 
with the enclosed 
insulation pipe. (If 
the insulator is 
insufficient, please 
sue commerical 
products.) 
 
Outdoor 
side 
Indoor 
side 
2~5mm 
φ65mm 
Large diameter pipe 
Small diameter pipe 
Unit: mm 
Tape 
Insulation pipe 
20~40 
200 
60 
100 
20~40 
60