10.3  FINAL STAGE OF INSTALLATION 
10.3.1.  INSULATION AND MAINTENANCE OF 
PIPE CONNECTIONS 
• 
The connected terminals should be completely 
sealed with heat insulator and then tied up with 
rubber strap. 
• 
Please tie the pipe and power line together with 
vinyl tape as shown in the figure showing the 
installation of Indoor and Outdoor units. Then fix 
their position with holders. 
• 
To enhance the heat insulation and to prevent 
water condensation, please cover the outdoor part 
of the drain hose and pipe with insulation pipe. 
• 
Completely seal any gap with putty 
 
10.3.2.  INSTALLATION OF REMOTE 
CONTROLLER 
• 
The remote controller can be placed in its holder 
which is fixed on wall or beam 
• 
To operate the remote controller at its holder, 
please ensure that the unit can receive signal 
transmitted from the controller at the place where 
the holder is to be fixed. The unit will beep when 
signal is received from the remote controller. The 
signal transmission is weaken by the fluorescent 
light. Therefore, during the installation of the 
remote control holder, please switch on the light, 
even during day time, to determine the mounting 
location of the holder. 
The controller must 
be hooked onto the 
hook at the lower 
part of the holder. 
Push in the remote 
controller in the 
direction as shown 
in figure below. 
 
 
  
 
 
Indoor 5  Indoor 6 
L5 
L6 
Insulation material for pipe connection 
Sleeve of 
protection pipe 
Indoor 5  Indoor 6 
L6 
L5 
Putty 
Putty 
Screw (2 pieces) 
Holder for 
Remote 
controller 
Remote 
control